Shanghai Weishi Mechanical CO.LTD.
2
1
On input interface you can monitor all input signals. When the input signal is
ON,the corresponding grid will tune red.The interface can present testing signals for
maintan.
Press
button on input interface, the system will switch to output
signal testing interface as picture(XVI).Pls reset before enter.
Figure
(
XVI
)
output signal testing interface
Pls reset after operation completed,otherwise the machine does not respond when
pressing the start button.
Four. List of Fault Information
No.
Fault Information
Processing method
E01
E01 Needle bar alarm
When PLC detect the drive alarming of needle bar, the enter
point of corresponding signal is I2B4.Please check whether the
drive of needle bar alarm.
Solution:Turn off the power when alarming, and wait for 15s
to restart the power,then press reset button to put the machine
into preparing state.
EO2
E02 X-axis alarm
When PLC detect the drive alarming of X-axis, please check
whether the drive of needle bar alarm.
Solution:Turn off the power when alarming, and wait for 15s