14-
Figure 4: Finger loads
5.2
Nominal Electrical Data
If the specified nominal data are exceeded, the gripping module may be damaged. If in doubt, clarify
your application with our technical sales department in advance.
Electrical operating data
Unit
CLG 30-006
Supply voltage
V
18 ... 30
Current consumption IDLE (inactive)
mA
40
Current consumption HOLDING (25% force)
mA
40
Current consumption HOLDING (100% force)
mA
60
Peak current max. (moving)
mA
800
C/Q pin
Input voltage range
V
0 ... 30
Threshold value "HIGH
V
13
Threshold value "LOW
V
8
Hysteresis
V
2,2
MX
MY
MZ
FC