5
EN
GL
ISH
TM
6
Connectors specifications
Pin
Function
1
Reserved
2
IN1
3
IN0
4
Reserved
5
Reserved
6
GND
7
+24 V/ 1.5 A IN
8
Reserved
9
OUT 1
10
OUT 0
6.1
Power Consumption
Type
Holding at 25%
Holding at 100%
GRIPKIT - CR EASY
0,05 A
0,25 A
6.1.1
Input circuit
The gripper module inputs support both NPN and PNP signals. The passive state is de
-
tected when the input is open (inactive). The active state is detected when the input is
actively pulled to either 0V (NPN) or 24V (PNP)
Input
Function GRIPKIT CR EASY
INO
Enable/Disable
IN1
GRIP
active: grab workpiece
passive: release workpiece
GRIPKIT CR EASY L
PIN 1
Summary of Contents for GRIPKIT CR EASY
Page 15: ...13 DEUTSCH TM 3 4 5 6 7...
Page 22: ...INSTRUCTION MANUAL GRIPKIT CR EASY...
Page 35: ...13 ENGLISH TM 3 4 5 6 7...