15.
NATURAL GAS TO PROPANE
CONVERSION KIT
(for KGT6T & KGT12T/GB)
THIS CONVERSION KIT SHALL ONLY BE INSTALLED BY A
QUALIFIED SERVICE AGENCY
For use at 0-2000 feet elevation on Honeywell valves Model
8305. For higher elevations consult the factory.
PART #’s
KE003716-1 kit for KGT6T (34,000 BTU)
KE003716-2 kit for KGT12T/GB (52,000 BTU)
Includes parts listed below:
APPROVED - APRIL 1, 2011
PART #
DESCRIPTION
QTY.
KE53406-2
Orifice, 1.75mm, Propane Gas (for KGT6T) . . . . . . .1
KE53406-12
Orifice, 2.15mm, Propane Gas (for KGT12T/GB) . . .1
KE603911-1
Conversion Label (for KGT6T) . . . . . . . . . . . . . . . . . .1
KE603911-2
Conversion Label (for KGT12T/GB) . . . . . . . . . . . . . .1
KE55240-4
Gas Valve Conversion Kit . . . . . . . . . . . . . . . . . . . . .1
KE603910
Instruction Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, and
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the
proper installation of this kit. The installation is not
proper and complete until the operation of the
converted appliance is checked as specified in the
manufacturer’s instructions supplied with the kit.
The gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the
conversion.
INSTRUCTIONS
1.
Shut off gas supply.
2.
Unplug electrical cord from source.
3.
Replace the gas orifice with the one supplied.
4.
Remove cover.
5.
Remove component mounting plate to get
access to the gas valve.
6.
Follow instructions in KE55240-4, GAS VALVE
CONVERSION KIT to convert gas valve to 10 in
W.C.
7.
Check inlet pressure is between 12-14 inches
W.C.
8.
Using instructions from kit KE55240-4 check
input rate of unit.
9.
On the underside of the console cover with
indelible marker place the following information:
Company, Name, Address & Date of Conversion.
10.
Reassemble unit.
11.
Install conversion label as close as possible to
the existing rating plate.
12.
Reconnect gas and electrical supply.
13.
Test kettle operation buy following
“INSTALLATION CHECK” section of the service
manual.
Photo showing manometer hooked up to outlet side of
valve.
KE603910
Install
conversion
label here.
WARNING:
CAUTION
!
!
Summary of Contents for Cleveland KGT12TGB
Page 27: ...26...