background image

Safety Notices

n

Warning

Read this manual thoroughly before operating, installing 

or performing maintenance on the equipment. Failure 

to follow instructions in this manual can cause property 

damage, injury or death.

 DANGER

Do not install or operate equipment that has been 

misused, abused, neglected, damaged, or altered/

modified from that of original manufactured 

specifications.

 DANGER

Keep power cord AWAY from HEATED surfaces. DO NOT 

immerse power cord or plug in water. DO NOT let power 

cord hang over edge of table or counter.

 DANGER

All utility connections and fixtures must be maintained 

in accordance with Local and national codes.

n

Warning

Authorized Service Representatives are obligated to 

follow industry standard safety procedures, including, 

but not limited to, local/national regulations for 

disconnection / lock out / tag out procedures for all 

utilities including electric, gas, water and  steam.

n

Warning

Do not store or use gasoline or other flammable vapors 

or liquids in the vicinity of this or any other appliance. 

Never use flammable oil soaked cloths or combustible 

cleaning solutions, for cleaning.

n

Warning

This product contains chemicals known to the State 

of California to cause cancer and/or birth defects or 

other reproductive harm. Operation, installation, and 

servicing of this product could expose you to airborne 

particles of glasswool or ceramic fibers, crystalline 

silica, and/or carbon monoxide.  Inhalation of airborne 

particles of glasswool or ceramic fibers is known to the 

State of California to cause cancer.  Inhalation of carbon 

monoxide is known to the State of California to cause 

birth defects or other reproductive harm.

n

Warning

Do not use electrical appliances inside the food storage 

compartments of the appliance, unless they are of the 

type recommended by the manufacturer.

n

Warning

Use caution when handling metal surface edges of all 

equipment.

n

Warning

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

concerning use of the appliance by a person responsible 

for their safety. Do not allow children to play with this 

appliance.

,

Caution

Use caution handling, moving and use of the R290 

refrigerators to avoid either damaging the refrigerant 

tubing or increasing the risk of a leak. Components 

shall be replaced with like components. Servicing shall 

be done by a factory authorized service personnel to 

minimize the risk of possible ignition due to incorrect 

parts or improper service.

Notice

Proper installation, care and maintenance are 

essential for maximum performance and trouble-free 

operation of your equipment. Visit our website www.

wbtkitchencare.com for manual updates, translations, 

or contact information for service agents in your area.

Notice

This product utilizes Ecomate blowing agent methyl 

formate

Summary of Contents for Delfield 4000P Series

Page 1: ...d Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Note additional shelves shown above Part Number 9294045C 03 22 Original Document Caution Read this instruction before operating this equipment Fresh Solutions Fit For You ...

Page 2: ...wool or ceramic fibers crystalline silica and or carbon monoxide Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm nWarning Do not use electrical appliances inside the food storage compartments of the appliance unless ...

Page 3: ...e Power Cord Chart 7 Refrigeration 8 Drain Connections 8 Caster Or Leg Installation 8 Leg Leveling 9 Caster and Leg Mounting Detail 9 Loosen Freezer Compressor Bolts 9 Section 3 Operation Controls Programming Settings 13 R290 Refrigerators 13 Freezers 14 Evaporator Fan Operation 14 Section 4 Maintenance Interior Cleaning 16 Preventing Blower Coil Corrosion 16 Exterior Cleaning 16 Drain 16 Cleaning...

Page 4: ...counter Refrigerator With Subtop And 3 75 Casters 406CA CE Undercounter Freezer Base With Stainless Steel Top 407P CE1 407P CE2 407P DHL CE1 407P DHL CE2 Undercounter Freezer Base With Stainless Steel Top 407 CE Undercounter Freezer With Subtop And 3 75 Casters 407CAP CE 407CA CE Serial Number Location The serial number on 400 series compact refrigerators and freezers is printed on the right side ...

Page 5: ... is intended for indoor use only Do not install or operate this equipment in outdoor areas Caution Do not position the air intake vent near steam or heat exhaust of another appliance The location selected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capabl...

Page 6: ...he vents clean and free of obstruction Legs or casters must be used and not removed Dimensions Model Length Depth Height 402P 27 69cm 28 5 72cm 39 5 100cm 403P 27 69cm 28 5 72cm 35 5 90cm 406P 27 69cm 28 5 72cm 35 5 90cm 406CAP 27 69cm 27 75 70cm 33 25 84cm 407P 27 69cm 28 5 72cm 35 5 90cm 407CAP 27 69cm 27 75 70cm 33 25 84cm ST4048P 48 122cm 28 5 72cm 39 5 100cm UC4048P 48 122cm 28 5 72cm 35 5 90...

Page 7: ...re start up GROUND FAULT CIRCUIT INTERRUPTER Ground Fault Circuit Interrupter GFCI GFI protection is a system that shuts down the electric circuit opens it when it senses an unexpected loss of power presumably to ground Welbilt does not recommend the use of GFCI GFI circuit protection to energize our equipment If code requires the use of a GFCI GFI then you must follow the local code The circuit m...

Page 8: ...or casters must be installed and the legs or casters must be screwed in completely to prevent bending When casters are installed the mass of this unit will allow it to move uncontrolled on an inclined surface These units must be tethered secured to comply with all applicable codes nWarning The unit must be installed in a stable condition with the front wheels locked Locking the front casters after...

Page 9: ... door remain closed CASTER AND LEG MOUNTING DETAIL A universal bolt hole pattern is provided on the bottom of the cabinet It will accommodate any leg or caster Simply line up the plate holes with the corresponding cabinet holes 3 40 86mm 2 82 72mm 1 75 44mm 2 14 54mm 0 94 24mm NOTE If hole pattern on caster leg matches the one above mount in middle set of holes 3 Caster 3234024 5 Caster 3234161 6 ...

Page 10: ...10 Part Number 9294045C 03 22 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 11: ...Part Number 9294045C 03 22 11 Section 2 Installation THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 12: ...t nWarning The operator of this equipment is solely responsible for ensuring safe holding temperature levels for all food items Failure to do so could result in unsafe food products for customers nWarning Overloading shelves can damage equipment or cause bodily injury nWarning Damp or wet hands may stick to cold surfaces nWarning Do not block the supply and return air grills or the air space aroun...

Page 13: ...ion that is being delayed by a timer external signal or disabled by another process that is already going on For example the compressor icon will flash if the cabinet temperature is above the cut in temperature but the control hasn t met the minimum compressor off time E0 Air probe error E1 Coil probe error LO Low temperature alarm 20 F for 90 minutes HI High temperature alarm 20 F for 90 minutes ...

Page 14: ...box at the rear of the unit It is factory set at mid range to maintain about 3 F 18 C box temperature To adjust for colder temperatures press and hold the set button until the current set point appears and is blinking on the screen Press the down arrow to adjust to the desired temperature Press the set button to save the temperature To adjust for warmer temperatures press and hold the set button u...

Page 15: ...rning When cleaning interior and exterior of unit care should be taken to avoid the front power switch and the rear power cord Keep water and or cleaning solutions away from these parts nWarning Never use a high pressure water jet for cleaning or hose down or flood interior or exterior of units with water Do not use power cleaning equipment steel wool scrapers or wire brushes on stainless steel or...

Page 16: ...ch drain can become loose or disconnected during normal use If you notice water accumulation on the inside of the unit be sure the drain tube is connected to the evaporator drain pan If water is collecting underneath the unit make sure the end of the drain tube is in the condensate evaporator The leveling of the unit is important as the units are designed to drain properly when level Be sure all d...

Page 17: ...ostat is not set too cold Also check gasket condition Cabinet temperature is too high Thermostat set too high Set thermostat to lower temperature Poor air circulation in cabinet Re arrange product to allow proper air circulation Exterior thermometer is out of calibration Re calibrate thermometer Excessive amount of warm product placed in cabinet Allow adequate time for product to cool down Prolong...

Page 18: ...18 Part Number 9294045C 03 22 Troubleshooting Section 5 406P and 4048P Wiring Diagram ...

Page 19: ...Part Number 9294045C 03 22 19 Section 5 Troubleshooting 407P Wiring Diagram ...

Page 20: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9294045C 03 22 ...

Reviews: