8
Part Number: 9294045C 03/22
Installation
Section 2
Refrigeration
Model
BTU/Hour
Capacity
Heat of
Rejection
Refg Charge
402P
1276
177
68g R290
403P
922
542
68g R290
403P-ES
922
542
68g R290
406P
1276
177
68g R290
406CAP
1276
177
68g R290
407P
922
542
68g R290
407P
922
542
68g R290
407CAP
922
542
68g R290
ST4048P
1276
452
68g R290
UC4048P
1276
452
68g R290
Export
406-CE
1276
177
213g R404A
406CA-CE
1276
177
213g R404A
407P-CE1
922
542
150g R290
407P-CE2
922
542
150g R290
407P-DHL-CE1
922
542
150g R290
407P-DHL-CE2
922
542
150g R290
407-CE
922
542
180g R404A
407CAP-CE
922
542
150g R290
407CA-CE
922
542
180g R404A
Drain Connections
n
Warning
If a refrigerated base does not have a condensate
evaporator supplied, you must connect the condensate
line to a suitable drain. Otherwise, water will collect on
the floor, causing a potentially hazardous situation.
n
Warning
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner’s responsibility to provide a container or
outlet for drainage.
Caster Or Leg Installation
DANGER
Legs or casters must be installed and the legs or casters
must be screwed in completely to prevent bending.
When casters are installed the mass of this unit will
allow it to move uncontrolled on an inclined surface.
These units must be tethered/secured to comply with
all applicable codes.
n
Warning
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owner’s and operator’s responsibility.
n
Warning
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg/caster. Place blocking
underneath the unit. Do not work underneath a raised
unit without proper blocking. Do not lift the unit more
than necessary to remove the leg/caster. Lifting the unit
too far can make the unit unstable.
,
Caution
All single-section units require that the swivel casters be
mounted on the front and rigid casters be mounted on
the rear.
1. Carefully place the unit on its back.
2. Located at each caster mounting location are 4 Phillips
head screws, for a total of 16 screws. Remove them.
3. Place a locking plate caster or leg over one of the front
holes, matching the 4 mounting holes to the pre-drilled
holes in the underside of the unit. Insert 4 Phillips head
screws and tighten. Repeat with the other locking front
caster or leg.
Summary of Contents for Delfield 4000P Series
Page 10: ...10 Part Number 9294045C 03 22 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...Part Number 9294045C 03 22 11 Section 2 Installation THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Part Number 9294045C 03 22 Troubleshooting Section 5 406P and 4048P Wiring Diagram ...
Page 19: ...Part Number 9294045C 03 22 19 Section 5 Troubleshooting 407P Wiring Diagram ...