30
Part Number: 9294045 07/19
Troubleshooting
Section 4
T40 Installation and Assembly
8. Thread electrical from the inside of the unit through the
supplied hole in the top. Do not cut another hole to thread
electrical.
9. Thread electrical wires through the top of control box
and connect to controls.
- Attach labeled electrical line the the corresponding
labeled connector on the control panel.
10. Pipe remote condensing unit to the refrigerant lines
coming out of the top of the cabinet. This should be done
by qualified refrigeration expert.
Put the compressor system in a suitable, well aired place
no farther than 25 feet from cabinet.
11. Place interior probes.
- Interior probe 1: Place on wall next to the
evaporator.
- Food probe: Place in food product for monitoring.
- Interior probe 2: Place on opposite side of cabinet
from evaporator 3/4 of the way to the top of the cabinet.
12. Unit must be plumbed with a P-trap to a drain for
evaporator water discharge.
13. Place cam plugs in all cam holes to cover them. Press
until seated in holes.
14. Install ramp and threshold onto the front of the outside
of the door.
Summary of Contents for Delfield CV10E
Page 22: ...22 Part Number 9294045 07 19 Troubleshooting Section 4 T40 BLast Chiller Shock Freezer ...
Page 25: ...Part Number 9294045 07 19 25 Section 4 Troubleshooting T5 T14D Refrigeration System Schematic ...
Page 26: ...26 Part Number 9294045 07 19 Troubleshooting Section 4 T5 T14D Wiring Diagram ...
Page 31: ...Part Number 9294045 07 19 31 Section 4 Troubleshooting Controller Buttons ...
Page 41: ...Part Number 9294045 07 19 41 Section 4 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...