5.7 TIMED BLAST FREEZING
- Press push-button 4 (relative LED lights up), then press
push-button 5 to select the timer mode (LED 5B on).
Display 14 shows the maximum chilling time (set by
default to 240 minutes). To modify this time, press push-
buttons 7 and 8 (time in minutes).
- Start up the cycle by pressing push-button 6. LED 5B and
push-button LEDs remain on and LEDs 13 flash throughout
the cycle. Internal cell temperature is shown on display 15.
- When the maximum chilling time has counted back to
0, the cycle is completed and the appliance automatically
switches to the set negative storage temperature for
an indefinite interval. LEDs illuminate and the beep is
activated when the cycle is finished (as in the freezing
cycle by temperature). The same applies for the storage
function. The factory setting for negative storage
temperature is -13F / -25C.
- Press push-button 6 to set the appliance to STOP status
(relative LEDs switches OFF), ready for a new cycle.
IMPRTANT: During chilling or shock freezing by time it's
possible to read the evaporator temperature by pressing
push-button 10.
Summary of Contents for Delfield CV10E
Page 22: ...22 Part Number 9294045 07 19 Troubleshooting Section 4 T40 BLast Chiller Shock Freezer ...
Page 25: ...Part Number 9294045 07 19 25 Section 4 Troubleshooting T5 T14D Refrigeration System Schematic ...
Page 26: ...26 Part Number 9294045 07 19 Troubleshooting Section 4 T5 T14D Wiring Diagram ...
Page 31: ...Part Number 9294045 07 19 31 Section 4 Troubleshooting Controller Buttons ...
Page 41: ...Part Number 9294045 07 19 41 Section 4 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...