114
Ice Machine Cycles Into Harvest Before Water Contact
with the Ice Thickness Probe
Step 1
Bypass the freeze time lock-in feature by
moving the ON/OFF/WASH switch to OFF and back to ON.
Wait until the water starts to flow over the evaporator,
then monitor the harvest light.
Step 2
Disconnect the ice thickness probe from the
control board terminal.
Step 2 Disconnect probe from control board terminal.
Monitoring Harvest Light
Correction
The harvest light stays off and
the ice machine remains in the
freeze sequence.
The ice thickness probe is
causing the malfunction. Verify
that the Ice Thickness probe is
adjusted correctly.
The harvest light comes on,
and 6-10 seconds later, the ice
machine cycles from freeze to
harvest.
The control board is causing the
malfunction.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......