164
UDP0310 SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
70/21
10.0-11.5
11.8-13.4
14.1-16.1
1.0-2.5
80/27
10.4-11.9
12.3-14.0
13.5-15.4
90/32
11.0-12.6
13.5-15.4
15.2-17.4
100/38
12.3-14.0
15.2-17.4
17.5-19.9
110/43
15.6-17.8
19.2-21.8
21.2-24.0
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Condenser °F/°C
Water Temperature °F/°C
50/10
70/21
90/32
70/21
305
265
225
80/27
295
255
235
90/32
280
235
210
100/38
255
210
185
110/43
205
170
155
Based on average ice slab weight of 2.44 - 2.75 lb (1107 – 1247 g).