20
Ice Machine Clearance Requirements
Self-contained Air-cooled
Top/Sides
5" (127 mm)*
Back
5" (127 mm)*
*The ice machine may be built into a cabinet.
Ice Machine Heat of Rejection
Series
Ice Machine
Heat of Rejection*
Air Conditioning**
Peak
UDP0080
1750
2600
UDP0140
2400
2900
UDP0240
2800
3300
UDP0310
3800
6000
* B.T.U./Hour
**
Because the heat of rejection varies during the ice
making cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing air
conditioning equipment where self-contained air-cooled
ice machines are installed.