Electrical Specifications
Air-cooled Ice Machine
Ice Machine Voltage Phase
Cycle
Max. Fuse/
Circuit Breaker
Total Amps
UDP0080
230/1/50
15
2.81
UDP0140
230/1/50
15
2.63
UDP0240
230/1/50
15
3.45
UDP0310
230/1/50
15
5.65
NOTE: Model/serial plate information overrides all data listed in
this chart.
n
Warning
All wiring must conform to local, and national codes.
n
Warning
The ice machine must be grounded in accordance with
national and local electrical code.