32
Remove Parts for Descaling
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
1. Remove the Harvest Float Switch and Ice Thickness
Float Switch
• Pull forward on the bottom of the bracket until
clear of the tab, then slide bracket upward to
remove the bracket and float as an assembly.
At this point, the float switches can easily be
descaled. If complete removal is desired, follow
the wires to the bulkhead grommet (exit point) in
the back wall. Pull the wire connector through the
bulkhead grommet, then disconnect the wire leads
from the connector.
NOTE: The wire from the top grommet goes to the ice
thickness float switch (front switch). The wire from the
bottom grommet goes to the Harvest float switch (side
switch).
Important
Reversing the mounting location of the ice thickness and
the harvest floats will result in a safety limit 2 failure.
• Do not disassemble float for descaling - Incorrect
reassembly will result in an ice machine that will not
harvest.
• The ice thickness float must be mounted to the front
of the water trough and the electrical connection must
be in the top bulkhead grommet.
• The harvest float must be mounted to the side of the
water trough and the electrical connection must be in
the bottom bulkhead grommet.
• The wire connectors for each float are different and
will not allow incorrect electrical bulkhead connection.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......