REMEDIAL CLEANING
This procedure can be performed between the bi-annual
detailed descaling and sanitizing cycles. This procedure
does not require removing the ice from the bin.
Step 1
Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner/Descaler
or Sanitizer.
Step 2
To start a cycle, press the Clean button. Water
will flow through the water dump valve and down the
drain. Wait until the water trough refills, then add the
proper amount of ice machine cleaner/descaler to the
water trough.
Model
Amount of Cleaner/Descaler
Part Number 9405463
UDP0140
2 ounce (60 ml)
UDP0240
5 ounces (150 ml)
UDP0310
5 ounces (150 ml)
Wait until the cycle is complete (approximately 22
minutes) then press the On/Off button.