Step 11
Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.
Step 12
Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a cloth or sponge to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
• Evaporator plastic parts - including top, bottom and
sides.
• Bin bottom, sides and top.
Do not rinse the sanitized areas.
Step 13
Replace all removed components.
Step 14
Reapply power and water to the ice machine
and place the toggle switch in the WASH position.
Step 15
Add the proper amount of Manitowoc Ice
Machine Sanitizer to the water trough.
Model
Amount of Sanitizer
Part Number 9405653
UDP0080
1.5 ounces (45 ml)
Step 16
Wait until the sanitize cycle is complete
(approximately 22 minutes) then place the toggle switch in
the OFF position, disconnect power and water supplies to
the ice machine.
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
Step 17
Repeat step 6 to remove parts for hand
sanitizing.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......