Full Bin Cycle
If the ice damper is held open by ice cubes the ice machine
shuts off. When the ice damper closes the ice machine
starts a new cycle at Initial Start-up From Shutoff. The ice
machine will remain off for a 3 minute delay period.
Thaw Cycle
The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 7 minutes a thaw
cycle initiates using the following sequence:
1. The compressor de-energizes.
2. The water inlet valve energizes and fills the water
trough.
3. The water pump energizes for 2 minutes and
circulates water over the evaporator.
If the bin switch did not open & close.
4. The water dump valve energizes and drains water
from the water trough.
5. Step 1 through 4 repeat.
6. If the damper does not open/close after step 5, the
control board assumes no ice is on the evaporator and
an initial startup cycle starts.
• If the bin switch opens & closes anytime during the
thaw cycle the ice machine starts a new freeze cycle.
• If the bin switch opens and remains open for 30
seconds at any point in the thaw cycle the ice machine
will enter an automatic shutoff cycle.
• The maximum water fill time for the thaw cycle is 105
seconds for each of the two possible thaw cycles.