5. Harvest
The water pump de-energizes stopping flow over the
evaporator. The rising level of water in the sump trough
diverts water out of the overflow tube, purging excess
minerals from the sump trough. The hot gas valve also
opens to divert hot refrigerant gas into the evaporator. The
refrigerant gas warms the evaporator causing the cubes to
slide, as a sheet, off the evaporator and into the storage
bin. The sliding sheet of cubes contacts the ice damper,
opening the bin switch. The momentary opening and re-
closing of the bin switch terminates the harvest cycle and
returns the ice machine to freeze (steps 3 - 4).
6. Automatic Shut-off
When the storage bin is full at the end of a harvest
sequence, the sheet of cubes fails to clear the ice damper
and will hold it down. After the ice damper is held open
for 7 seconds, the ice machine shuts off. The ice machine
remains off for 3 minutes before it can automatically
restart. The ice machine remains off until enough ice has
been removed from the storage bin to allow the ice to fall
clear of the damper. As the ice damper swings back to the
operating position, the bin switch re-closes and the ice
machine restarts (steps 1 - 2), provided the 3 minute delay
period is complete.