80
Safety Limit 3
If the freeze time reaches 4 minutes and water is not
sensed (float remains down for 10 continuous seconds) the
ice machine stops.
• Safety Limit 3 is bypassed on the initial cycle (manual
start or after a full bin/safety limit condition). For all
subsequent cycles if the freeze time reaches 4 minutes
and water is not sensed, the ice machine stops and
initiates a 30 minute delay period. Control board
lights SL#1 and SL#2 along with the touch pad Service
(wrench) light will flash on/off at 1 second intervals.
• The ice machine automatically restarts at the end of
the 30 minute delay period and stops flashing the
control board and Service (wrench) lights.
• If 100 consecutive failures occur the ice machine stops
and the touch pad Service (wrench) light remains
energized.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......