78
CONTROL BOARD TEST MODE
NOTE: The ice damper/bin switch can be open or closed
and does not effect the operation of the test mode.
To enter the test mode press and hold the test switch
on the control board for 3 seconds. Refer to “Electronic
Control Board UDP0140/UDP0240/UDP0310” on page
174 for test button location. The control board test mode
performs the following functions for a 2 minute time
period:
• Energizes all control board relays
• Energizes all control board lights
• Energizes all touch pad control lights
After the 2 minute test period the control board will
complete 500 ice making cycles, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.
OPERATING ICE MACHINE WITH BIN AND TOUCH PAD
REMOVED
The ice machine is designed to allow diagnostic procedures
to be performed with the bin removed or to run ice
making cycles if a touch pad is defective. The touch pad is
attached to the bin and is disconnected during the removal
process. Use the control board test mode to operate the
ice machine without connecting the touch pad. Refer to
“Electronic Control Board UDP0140/UDP0240/UDP0310”
on page 174 for test button location
NOTE: Software versions before 2.70 operate for 1 cycle
in test mode. Software versions after 2.70 operate for 500
cycles in test mode.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......