Part Number 000007661 Rev01 05/17
39
Step 8
Disconnect power, then drain the water from
the evaporator and reservoir through the evaporator/
reservoir drain line - Using a pitcher, fill and drain the
evaporator/reservoir 4 times and reinsert the hose into
the hose clip.
Step 9
Refer to chart and premix water and sanitizer.
Amount of Luke Warm
Water
Amount of Sanitizer
1 Gallon (4 L) Water
1/2 ounce (15 ml)
Step 10 Fill reservoir and evaporator with sanitizer/
water solution.
Step 11 Step 11 Verify the compressor rocker switch is
in the OFF position, then reconnect power and run the
gearmotor for 10 minutes.
• During the 10 minute period rinse cleaner from
compression nozzle with potable water and then
soak in sanitizer/water solution.
Step 12 Move the compressor rocker switch to the ON
position. The ice machine will make ice with the sanitizer/
water solution and deposit the ice in the bin/ dispenser.
Make ice for 5 minutes - add sanitizer/water solution as
the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop
below the sensing probes. The ice machine will start a 20
minute delay period if the sensing probes lose contact
with the water for more than 10 seconds.
Step 13 Move the compressor rocker switch to the OFF
position and disconnect power.
Step 14 Drain the evaporator/reservoir and reinsert the
drain hose into the hose clip.
Step 15 Reinstall the ice compression nozzle and
reservoir cover. Verify the ice tube is in place and does not
contact the condenser fan blade.
Summary of Contents for Manitowoc R
Page 1: ...Part Number 000007661 Rev01 05 17 R Model Flake Nugget Ice Machine Technician s Handbook...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 22: ...THIS PAGE INTENTIONALLY LEFT BLANK 22 Part Number 000007661 Rev01 05 17...
Page 220: ...THIS PAGE INTENTIONALLY LEFT BLANK 220 Part Number 000007661 Rev01 05 17...
Page 224: ...224 Part Number 000007661 Rev01 05 17 RF0300 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 252: ...252 Part Number 000007661 Rev01 05 17 RNS0308 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 260: ...260 Part Number 000007661 Rev01 05 17 RNS1000 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 270: ...270 Part Number 000007661 Rev01 05 17 RF1200 RFS1200 WATER COOLED 1 2 3 4 5 6 7 8...
Page 272: ...272 Part Number 000007661 Rev01 05 17 RF2300 RFS2300 AIR COOLED 1 2 3 4 5 6 7 8 8...
Page 274: ...274 Part Number 000007661 Rev01 05 17 RF2300 RFS2300 WATER COOLED 1 2 3 4 5 6 7 8 8...
Page 282: ...282 Part Number 000007661 Rev01 05 17 RN0400 RN1000 RN1400 AIR WATER COOLED 1 2 3 4 5 6...
Page 286: ...THIS PAGE INTENTIONALLY LEFT BLANK 286 Part Number 000007661 Rev01 05 17...
Page 287: ......