10–3
SCANTEAM 3700 Wedge Technical Manual
millimeters in brackets [mm]
3.5”
[88.9]
Mounting Screw Location #6–32 UNC–2B or M3.5 (4
Places)
1.75”
[44.5]
.375”
[9.5]
2.75”
[69.9]
Side View
Top View
.31” [7.9]
Nominal Optics Center Line
✺
✺
Installation should provide adjustment to align the optical center line
on the intended target. This adjustment should account for tolerance
variation in the 3700 Wedge scanner, as well as the host equipment.
Front View
3.1” [78.7]
.42” [10.7
]
Scanner Window
.2” [5.1]
1.05”
[26.7]
2.9”
[73.7]
Mounting Surface
Focal Plane
2.73”
[69.3]
1.95”
[49.5]
REF
Figure 5. Mounting Dimensions for the 3700 Wedge