4.6 Configuration Example
The following example illustrates the proper programming sequence to
configure wand parameters to specific operating values.
Example: Configure the SCANTEAM 6180 parameters to the following
values:
Symbology:
Code 3 of 9 (Code 39)
Maximum Length:
14
Minimum Length:
8
Append Option:
Enabled
Start/Stop Character:
Included
Check Character:
Required
Check Character:
Transmit
Baud Rate:
4800
Parity:
Space
Preamble:
STX
Code ID
Postamble:
ETX
Intercharacter Delay:
25 ms
Indicator Control:
Beep on Reset
Beep on Good Read
Append Buffer:
Enabled
Refer to the Selections/Variables table on the INPUT/OUTPUT
PARAMETERS & FORMAT and SYMBOLOGY SELECTIONS pages of
the Programming Menu.
Program these operating parameters following the scanning sequence
below.
FUNCTION
SELECTION VARIABLE
Enter SYMBOLOGY
SELECTION
Menu Page
ENTER
Set All Wand Parameters W.A.
To DEFAULT Values
DEFAULT
Scanning sequence continued on next page.