WELGER RP 235 • E-LINK
11
5.1 The
display
Tying
mode
(see page 12)
Hydraulic
switch
(see page 13)
Operating
parameter
(see page 16)
manual
twine tying
Adjustment
pick-up
Bale density
(here: set value 5)
automatic twine tying
Adjustment
bottom door
Net layers
(here: set value 1.5)
Manual net tying
Adjustment cutting device
(here: 8 knives selected)
Automatic net tying
automatic
combined tying
The PTO speed regulates the optional electric Lubrication pump and the measurement of the machine
working time. Both will be activated at a PTO speed larger than 100 rpm.
Animation:
Material flow into the baler
Bale counter
(active daily counter)
Machine
working time
(active daily counter)
Bar chart
for representation of the bale
density with display of the set
value (arrow)
Battery voltage