WELGER RP 235 • E-LINK
29
8.1.3 Standard diagnosis – Actors
Actors are e.g. electro-valves of the hydraulic system.
In the
ACTOR DIAGNOSIS
ACTOR DIAGNOSIS
ACTOR DIAGNOSIS
ACTOR DIAGNOSIS
, the status of the actor
channels is displayed. The functions can be tested
manually
(Diagnosis Manual) or
automatically
(Diagnosis Automatic).
Attention, danger of injury!
Standard diagnosis may only be performed after the
machine has been stopped: Switch off tractor engine,
wait until machine has stopped, disconnect hydraulic
supply to the machine.
Note!
The number of the actors shown or of the display
pages depends on the settings in the "Setup" menu
(see chapter 6 "Setup" menu).
Manual
To toggle between
DIAGNOSIS ACTORS MAN
DIAGNOSIS ACTORS MAN
DIAGNOSIS ACTORS MAN
DIAGNOSIS ACTORS MANUAL
UAL
UAL
UAL
and
DIAGNOSIS ACTORS AUT
DIAGNOSIS ACTORS AUT
DIAGNOSIS ACTORS AUT
DIAGNOSIS ACTORS AUTOMATIC
OMATIC
OMATIC
OMATIC
:
Press button
<START/STOP>.
Select actor channel: keys
and
Actor On or Off: keys
and
The following symbols are used for the actor status:
Symbol
Actor status
Actor has been triggered (+) and has switched (+).
Actor should be triggered (+), but has not switched (–).
Attention, fault! e. g. actor channel in control unit
defective.
Actor not triggered (–), but has switched (+). Attention,
fault! e. g. short circuit or broken wire.
Actor has not been triggered (–) and has not switched
(–).
Summary of Contents for E-LINK RP 235