Filling the Inert Gas Supply Tank
The inert gas being used to pre-charge the LS-14 must be compatible with the seals in the LS-14. Welker recommends using
nitrogen or helium as the inert gas supply.
The relief valves and gauges must be adequate for the pressure used to pre-charge the LS-14.
Pre-charging must be complete before product is supplied to the system.
Inert gas tanks are shipped empty from the manufacturer.
16.
Determine the configuration of the inert gas supply valves on the LS-14 (
). If the LS-14 is equipped with option
1, continue to step 17. If the LS-14 is equipped with option 2, proceed to step 27.
Figure 10: Inert Gas Supply Valve Configuration Options
16
IOM-131
MODEL: LS-14
REV: F
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331