12.
As necessary, connect an appropriate electrical supply to the EHUC (
13.
As necessary, connect a DC 24 V electrical supply to the level indicator (
or
).
14.
As necessary, connect the solenoid to the PLC. Refer to industry standards for appropriate electrical connections to
interface with the PLC.
15.
As necessary, set the PLC to the desired proportional to flow sampling frequency based on the sampling actuation
equations provided (
Figure 9: Sampling Frequency Equations
Never fill the cylinder above 80% of its capacity. Allow at least 20% room for product expansion should the cylinder be exposed
to increased temperatures.
Note that there are 3,785 cc in 1 US gallon. The LS-14 may be 1½, 3, 5, or 10 US gallons at 80%.
15