5
IOM-181 | MODEL: ECOSYSTEM™ WITH XLT CONTROLLER | REV: C
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department: 281.491.2331
1.4 Specifications
The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your
company's needs.
Please note that the specifications may vary depending on the customization of your equipment.
Table 1: ECOsystem™ Specifications
Application
Vaporized Odorant Infusion
Electrical Connection
AC 120 V
DC 12 V
DC 24 V
Odorant Tank Volume
5 US Gallons (
18 L
)
20 US Gallons (
75 L
)
50 US Gallons (
189 L
)
60 US Gallons (
227 L
)
100 US Gallons (
378 L
)
120 US Gallons (
454 L
)
250 US Gallons (
946 L
)
500 US Gallons (
1892 L
)
Others Available
Features
Odorant Tank Level Gauge
Skid With 110% Containment
Temperature Transmitter
Touch Screen Controller
Valve Section (See
Table 2
)
Options
Flag Tracker Level Indicator
Heater for Controller Enclosure
NEMA 4 or NEMA 7 Enclosure for Controller
Solar Panel
Steel Building
Table 2: Valve Section Specifications
Tubing Size
Low Flow:
¼" (
0.6 cm
)
High Flow:
³∕8" (
0.9 cm
)
Variable Flow:
¼" and ³∕8" (
0.6
and
0.9 cm
)
Features
2-Way Solenoid Valve
Flow Switch
Regulator for Natural Gas Supply
Welker F-5 Filter Dryer for Natural Gas Supply
Options
Backup Solenoid
Enclosure
Heater With Thermostat
Low Flow Solenoid
Volume Bottle
(for Systems With ³∕8" (
0.9
cm) Tubing)