background image

 

                                      -                                                                      10 - 

 

3. If leak is detected at regulator/cylinder valve connection, disconnect, reconnect, and perform another leak 
check. If you continue to see bubbles after several attempts, cylinder valve is defective. Call our customer 

service hotline at 

1-866-985-7877

, 9 a.m. – 6 p.m., EST, Monday – Friday   

 

IF NO BUBBLES APPEAR AT ANY CONNECTION, THE CONNECTIONS ARE SECURE. 
Note: Whenever gas connections are loosened or removed, you must perform a complete leak check. 

 
 

 

 
 

 

 

 
 

 

 
 

Caution: 

Do not attempt to operate this appliance until you have read and understand all Safety Information in 

this manual and all assembly is complete and leak checks have been performed. 

 

Before Turning Gas Supply ON

1. Your heater was designed and approved for OUTDOOR use only. Do NOT use it inside a building, garage, or 
any other enclosed area. 

2. Make sure surrounding areas are free of combustible materials, gasoline, and other flammable vapors or 
liquids. 

3. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no 
leaks. 
4. Be sure the cylinder cover is clear of debris. Be sure any component removed during assembly or servicing is 

replaced and fastened prior to starting. 
 

Before Lighting

1. Heater should be thoroughly inspected before each use, and by a qualified service person at least annually. If 

re-lighting a hot heater, always wait at least 5 minutes. 
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should be leak 

tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose assembly 
specified by the manufacturer. 
 

Lighting

NOTE

: For initial start or after any cylinder change, hold the control knob in for 2 minutes to purge air from all 

gas lines before proceeding. 

1. Turn the control knob to the “OFF” position. 

2. Fully open the LP cylinder valve. 
3. Turn the control knob half way between the small flame and the large   

flame symbols. 
4. Push control knob in and then push the RED igniter button to ignite the 
main burner. Repeat until the burner ignites. Keep the control knob fully   

pushed in for an additional 30 seconds after the burner ignites, then   
release the control knob. 

5. To increase the flame, turn the control knob clockwise toward the large 
flame symbol. To decrease the flame, turn the control know counter   

clockwise towards the small flame symbol. 
6. To turn the appliance OFF, push down the Control knob and turn   

clockwise to the OFF position. 
7. Wait at least 5 minutes before attempting to re-light the heater. 
8. Turn the gas cylinder valve to OFF or closed. 

If you experience any ignition problems, please consult “Troubleshooting” on page 13. 

Caution

: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the burning of oils used in the manufacturing will 

appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should NOT produce thick black smoke. 
 
 

OPERATING INSTRUCTIONS

 

Summary of Contents for 61176

Page 1: ...186 ATTACH YOUR RECEIPT HERE Serial Number ___________ Purchase Date ______ Questions problems missing parts Before returning to your retailer call our customer service hotline at 1 866 985 7877 9 a m...

Page 2: ...ctns B Reflector Center Cap 1 C Head Assembly 1 packed in 1 inner ctn D Tank Housing 1 E Gas Hose 1 attached to Head Assembly F Upper Post 1 G Regulator 1 packed with Head Assembly H Lower Post 1 I P...

Page 3: ...al Keep this manual for future reference and to educate new users of this appliance This manual should be read in conjunction with the labeling on the appliance Safety precautions are essential when a...

Page 4: ...4 SAFETY INFORMATION...

Page 5: ...ntact customer service for replacement parts ESTIMATED ASSEMBLY TIME 60 minutes Tools Required for Assembly NOT included Phillips screwdriver w medium blade Leak Detection Solution Adjustable wrench 2...

Page 6: ...and then tighten all bolts with a wrench Hardware Used 3 x AA Bolt M8x16 3 Attach the Lower Post H to the Post Supports I Once you have tightened the bolts holding the Post Supports I to the Base J al...

Page 7: ...te There is a small piece of protective foam located in the neck of the Head Assembly that MUST be removed prior to attaching Head Assembly to the Upper Post Route Gas Hose E down into Upper Lower pos...

Page 8: ...ad Assembly C and slide the assembled Reflector over the 3 bolts that extend from the Head Assembly Use the 3 M8 Wing Nuts EE and 3 M8 Washers GG to secure the assembled Reflector to the Head Assembly...

Page 9: ...s cylinders of the U S Department of Transportation DOT or the standard for cylinders spheres and tubes for transportation of dangerous goods and commission CAN CSA B339 The cylinder must have a liste...

Page 10: ...2 Inspect the hose assembly for evidence of excessive abrasion cuts or wear Suspected areas should be leak tested If the hose leaks it must be replaced prior to operation Only use the replacement hos...

Page 11: ...able 3 No alterations have been made 4 All gas connections are secure and do not leak 5 Wind velocity is below 10 mph 6 Unit will operate at reduced efficiency below 40 degrees F 7 Heater is for use o...

Page 12: ...n can damage heater and render it unsafe for use Clean burner holes by using a heavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon deposits may create a fire hazard Cle...

Page 13: ...ose connection Check all fittings Igniter fails Use stick lighter to manually light Gas pressure low with valve open full Replace cylinder or regulator New cylinder or 1st ignition Purge air from line...

Page 14: ...RUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY IN NO EVENT WILL WELL TRAVELED LIVING OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR AN...

Reviews: