background image

 

 

 

                                 

       WELL mPBX-U110R Installation Guide  

 

Figure

 

2

3

 

WELL

 

mPBX

U110R

 

Rear

 

Panel

 

 

 

LED

 

Status

 

Description

 

Indication

 

On

 

The

 

power

 

is

 

switched

 

on

 

Power

 

Power

 

status

 

Off

 

The

 

power

 

is

 

switched

 

off

 

Blinking

 

mPBX

 

is

 

running

 

properly

 

RUN

 

mPBX

 

status

 

Not

 

Blinking/Off

 

mPBX

 

goes

 

wrong

 

 

Ports

 

Description

 

RJ11

 

ports

 

FXS

 

port

:

 

For

 

the

 

connection

 

of

 

analog

 

phones.

   

Ethernet

 

ports

 

WELL

 

mPBX

U110R

 

provides

 

two

 

10/100M

 

adaptive

 

RJ45

 

Ethernet

 

ports,

 

marked

 

as

 

LAN

 

and

 

WAN.

   

LAN

 

port

:

 

LAN

 

port

 

is

 

for

 

the

 

connection

 

to

 

Local

 

Area

 

Network

 

(LAN).

   

WAN

 

port

:

 

WAN

 

port

 

is

 

the

 

network

 

port

 

for

 

the

 

connection

 

to

 

internet.

 

It

 

supports

 

‘DHCP

 

server’,

 

‘PPPoE/dynamic

 

DNS’,

 

and

 

“static

 

IP”

 

for

 

IP

 

address

 

assignment.

 

E1/T1

 

ports

 

For

 

the

 

connection

 

to

 

E1

 

line

 

or

 

the

 

E1

 

port

 

of

 

traditional

 

PBX.

   

Audio

 

Input

 

port

 

For

 

the

 

connection

 

to

 

a

 

music

on

hold

 

source

 

Audio

 

output

 

port

 

For

 

the

 

connection

 

to

 

a

 

paging

 

system.

 

Reset

 

Button

 

Press

 

the

 

reset

 

button

 

to

 

restore

 

the

 

factory

 

defaults

 

Please

 

make

 

sure

 

that

 

you

d

 

like

 

to

 

reset

 

because

 

once

 

reset,

 

the

 

previous

 

configurations

 

would

 

be

 

erased

 

automatically.

 

Power

 

port

 

For

 

the

 

connection

 

of

 

a

 

power

 

adapter

 

to

 

input

 

100~240V

50~60HZ

 

AC

 

power

         

USB

 

port

   

 

Console

 

port

 

For

 

debugging

 

 

2.3

 

Specifications

 

and

 

Operating

 

Environment

   

 

Description

 

Size

 

L213

 

*

 

W

 

160

 

*

 

H

 

44

 

(mm)

 

Power

 

Supply

 

220V,50

60Hz

 

                                                                                                                              5/13 

Summary of Contents for mPBX-U110R

Page 1: ...WELL mPBX U110R Installation Guide WELL mPBX U110R Installation Guide Version V1 0 Date 25th July 2012 1 13 ...

Page 2: ...Installation instructions 6 3 2 1 Connection of ethernet ports 6 3 2 2 Connection of E1 T1 ports 7 3 2 3 Connection of FXS ports 8 3 2 4 Power connection 9 3 2 5 Overall flow chart 9 4 WELL mPBX U110R basic configurations 9 4 1 Factory defaults 9 4 2 Logging in the web configuration panel 10 4 3 Network settings 11 4 4 Extensions and setup management 11 4 5 Configuring terminals 11 4 6 Making rece...

Page 3: ...ey are able to select their local language for Web GUI and Voice Prompt Furthermore it is renowned for its user friendly web configuration panel which is easy accessible and self evident making configuration a trouble free job This Guide explains how to install WELL mPBX U110R how to configure WELL mPBX U110R via web interface how to add extensions and make receive calls via PSTN lines 1 Preparati...

Page 4: ...WELL mPBX U110R Installation Guide 2 Hardware Specifications 2 1 Overview Figure 2 1 WELL mPBX U110R 2 2 LED Indicators and Ports Figure 2 2 WELL mPBX U110R Front Panel 4 13 ...

Page 5: ...etwork port for the connection to internet It supports DHCP server PPPoE dynamic DNS and static IP for IP address assignment E1 T1 ports For the connection to E1 line or the E1 port of traditional PBX Audio Input port For the connection to a music on hold source Audio output port For the connection to a paging system Reset Button Press the reset button to restore the factory defaults Please make s...

Page 6: ...and high frequency and high current devices Is using independent power junction box and effective anti grid interference measures have been taken Mechanical load Please make sure that the device is placed steadily to avoid any accident that might cause damage If placed on the desktop please ensure it is horizontally placed 3 2 Installation Instructions After placing WELL mPBX U110R in a suitable p...

Page 7: ...equence of E1 port From the above table we can see that the No 1 and No 2 pins of WELL mPBX U110R E1 port is for receiving data No 1 for receiving data No 2 for receiving data while No 4 and No 5 is for transmitting data No 4 is for transmitting data No 5 is for transmitting data When connected to the E1 line RX of E1 port should be connected to TX of E1 line RX of E1 port should be connected to T...

Page 8: ...ion Guide Figure 3 2 Connection of E1 T1 port 3 2 3 Connection of FXS ports The FXS port could be connected to an analog phone with a phone line The connection could be depicted as below Figure 3 3 Connection of FXS ports 8 13 ...

Page 9: ...cator lights would turn on Please switch off the power before plugging or unplugging the cables 3 2 5 Overall Flow Chart Figure 3 4 Overall Flow Chart 4 WELL mPBX U110R Basic Configurations 4 1 Factory Defaults WELL mPBX U110R provides web based configuration interface for administrator and account user The user can manage the device by log in the web interface The factory default IP address LAN 1...

Page 10: ... same segment with the PC and which can be connected when commit Ping mPBX IP address command Start the browser on PC In the address bar enter the IP address click enter button and then you can see WELL mPBX U110R Web Configuration Panel login page See Figure 4 1 Figure 4 1 mPBX Web Configuration Panel Login Page Enter the Admin User Name and Password to log in Figure 4 2 mPBX Admin Configuration ...

Page 11: ... Static IP address please select this option and enter the LAN parameters IP address subnet mask default gateway DNS etc 3 If mPBX is connected to ADSL adapter directly please select PPPoE option and enter the ADSL user name and password LAN Settings Click Network Settings LAN Settings on the left menu bar of the web configuration interface LAN port is used for the interoperability of IP terminals...

Page 12: ...by dialing the other s extension number 2 Outbound calls Firstly please connect a PSTN line to the first FXO port Then the default extensions are able to make outbound calls via this trunk by simply dialing 9 phone number The is Key as Send Note The dial pattern of the default outbound route is 9 But if the user has changed it please dial the new prefix instead of the digit 9 when making outbound ...

Page 13: ...e installation and basic settings of WELL mPBX U110R for making and receiving calls For more functionality and advanced settings of WELL mPBX U110R please refer to the relative documents as below WELL mPBX U110R Datasheet WELL mPBX U110R Administrator s Guide WELL mPBX U110R User s Guide The End ...

Reviews: