The Weller WSD 151 / PUD 151R soldering station also offers the
following functions:
−
Automatic tool detection and activation of corresponding control
parameters
−
Digital temperature control
−
Zero voltage circuit
−
Antistatic device design in accordance with ESD safety
−
Different equipotential-bonding possibilities on the device
(standard configuration)
−
Sockets for external input unit WCB 2 for extending the range of
functions (see the table below)
−
Socket for external control system ; PUD 151R only (robot
application)
Additional function via the WCB 2 Description
Offset
The real temperature of the soldering iron can be changed by
±
40 °C by entering a temperature offset.
Setback and auto-off function
When the soldering tool is not in use, the temperature is reduced
to the standby temperature (150 °C/999°F) after the set setback
time has elapsed.
The setback time can be set from 0 to 99 minutes. A flashing
display shows the setback status. Press a button or the finger
switch to cancel the status display. The setpoint value is
displayed briefly. After a period equal to three times the setback
time has elapsed, the auto-off function is activated. The soldering
tool switches off (dash flashes on the display).
Lock
Locks the setpoint temperature. Settings cannot be changed
once the soldering station has been locked.
°C/°F
Switching the temperature display from °C to °F and vice versa.
Window
It is possible, starting from a set, locked temperature, to set a
temperature window of ± 99 °C (± 180 °F) with the aid of the
WINDOW function.
The WINDOW function is used to set a temperature window for
devices with a potential-free contact (optocoupler output). If the
actual temperature is within this window, the potential-free
contact (optocoupler output) is switched through.
Cal
Adjusts the soldering station and factory settings (FSE). Resets
all setting values to 0, temperature 350 °C (660 °F).
PC interface
RS232
Temperature gauge
Integrated temperature gauge for thermal element type K
Summary of Contents for PUD 151R
Page 11: ...EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT DE WSD 151 PUD 151R Operating Manual ...
Page 31: ...WSD 151 Exploded Drawing DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT ...
Page 32: ...WSD 151 Circuit Diagram ...
Page 33: ...PUD 151R Exploded Drawing DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT ...
Page 34: ...PUD 151R Circuit Diagram ...