Operating Instructions 

 

Weller Model WHP-300 Hot-Plate Solderer De-Solderer 

 

 

 

Description 

 
 

The Preheating and Reflow System WHP 300 is eminently suitable for soldering and 
unsoldering tasks in hybrid technology. This device brings the carrier material to the working 
temperature for perfect soldering operations without causing any thermal damage to the base 
material. The Heating Plate HP 300 is electrically isolated from the power supply mains and 
operates with safe low voltage of 27 V AC. The heated area of 100 x 160 mm (European 
format) is heated uniformly. Temperature regulation is performed by analogue means. The 
desired temperature can be set continuously with a rotary potentiometer control over the 
range from 50°C to 300°C. The set point temperature and the actual temperature are displayed 
in digital form. The digital temperature indicator can be switched to the desired display mode 
(set point or actual value) with a sliding switch. The digital display also contains a luminous 
spot for visually checking the action of the temperature controller. As option, a facility is 
available for controlling the temperature with an external sensor directly on the heated 
component. Switchover to the external sensor takes place automatically when plugging-in the 
6.35 mm jack plug on the front of the unit. The case is coated with a permanent electrically 
conducting lacquer. A ground potential equalisation connection can be made if required via 
the 3.5 mm switching jack-plug socket on the rear of the unit. The mains primary circuit of the 
unit is equipped with a resetable current overload cut-out device. This current overload cut-
out device can be reset by pressing the red button after clearing the cause of the current 
overload fault. 

Summary of Contents for WHP-300

Page 1: ...et point temperature and the actual temperature are displayed in digital form The digital temperature indicator can be switched to the desired display mode set point or actual value with a sliding switch The digital display also contains a luminous spot for visually checking the action of the temperature controller As option a facility is available for controlling the temperature with an external ...

Page 2: ... should be set to SET POINT Switch on the control unit at its mains switch and set the desired temperature on the rotary potentiometer control The red spot to the right of the display digits lights up This red spot indicates the temperature controller action Continuous illumination means that the actual temperature is below the set point temperature that is the system is heating up Flashing of the...

Page 3: ...ility or liability for damage or injury caused by unauthorised tampering or by usage deviating from the proper usage as described in the operating instructions These operating instructions and the warnings contained therein must be read attentively and placed clearly visible in the vicinity of the soldering device Failure to observe the warnings can lead to accidents and injuries or damage to heal...

Page 4: ...the appropriate soldering tool Don t use a soldering tool whose performance is not adequate for your work Never use the soldering tool for purposes for which is was not designed 8 Wear suitable work cloths There is a danger of burning yourself with liquid solder Wear the corresponding protective clothing in order to protect yourself against burns 9 Protect your eyes Wear protective eyewear When wo...

Page 5: ...WHP 300 Man 4p doc Page 5 12 31 2002 AlanD Page 5 12 31 2002 The document is also saved as a PDF file with the makers original data sheet attached to conserve file size ...

Reviews: