10
Note:
The power units have been adapted to hold a
medium-sized soldering tip. Discrepancies may occur if the
tip is changed or a different shaped tip is used, but these
can be overcome using the offset function.
6.3 Switching off the device
Press the
+
and
–
button until "
OFF
" appears on the
display
Note
If you do not intend to use the soldering iron for longer
periods, set the disconnecting switch to "
O
".
Make sure that the battery is charged at least 50 %, see
Information on the application note for battery on page
8
.
Soldering tip change
Caution, risk of burning
!
Tools are not required to change the soldering tip.
Only change a cold soldering tip.
The soldering tip is inserted in handle (24) and can be
removed by simply pulling the soft grip on the soldering tip
(25).
Important
- Change the soldering tip when cold.
- Always ensure that the soldering tip is seated properly.
6.4 Switching the temperature unit
Switching the temperature unit from "
°C to °F
" (8) or vice
versa.
1. Select the menu item "
°C / °F
" in the menu.
2. Set the temperature unit with the
-
or
+
button.
3. The display reverts to the normal temperature
if no buttons are pressed for about 2 seconds.
The stem is fitted with a sensor that monitors device use,
i.e. when the stem is inserted in the rest, the temperature
is reduced to standby temperature after 5 minutes and
switched off after 5 more minutes.
7. Special functions for
WSM 1 / WSM 1C
Setting the standby temperature
The following standby temperatures are available
(150 °C – 250 °C / 300 °F – 480 °F).
1. Select the "
STANDBY
" (18) menu item in the menu.
2. Set the setpoint value for the standby temperature with
the
-
or
+
button.
3. The display reverts to the normal temperature
if no buttons are pressed for about 3 seconds.
Setting the automatic switch-off time (AUTO-OFF)
The following AUTO-OFF time settings (17) are available:
- "10 – 60 min." AUTO-OFF time, individually adjustable
1. Select the menu item "
OFF
" in the menu.
2. Set the AUTO-OFF setpoint time value with the
-
or
+
button.
English
Actual value
display
Setpoint value
display
Preset standby
temperature
200 °C
+ or -
Preset SETBACK
TIME after
5 min of disuse
Preset OFF-
SET TIME after
5 min of disuse
OFF
OFF
+ and -
2 s
4 s
6 s
8 s
10 s
12 s
14 s
OFF
STANDBY
AUTO OFF
OFF SET
SETBACK
°C / °F
LOCK
OFF
after 3 s without pressing button