PRIMING MODE – M019*
This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have
primed.
*M019 is a Message Code.
Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the
system will automatically return to normal heating and filtering at the end of the priming mode. During
the priming mode, the heater is disabled to allow the priming process to be completed without the
possibility of energizing the heater under low-flow or no-flow conditions. Nothing comes on
automatically, but the pump(s) can be energized by pushing the “Jet” buttons.
If the spa has a Circ Pump, it can be activated by pressing the “Light” button during Priming Mode.
EXITING PRIMING MODE
You can manually exit Priming Mode by pressing a “Temp” button (Up or Down). Note that if you do not
manually exit the priming mode as described above, the priming mode will be automatically terminated
after 4-5 minutes. Be sure that the pump(s) have been primed by this time.
Once the system has exited Priming Mode, the top-side panel will momentarily display the set
temperature but the display will not show the temperature yet, as shown below. This is because the
system requires approximately 1 minute of water flowing through the heater to determine the water
temperature and display it.
PUMPS
Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if
equipped.
If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after
30 minutes. The high-speed will time out after 15 minutes.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa
is in Ready Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa
temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on
automatically, it cannot be deactivated from the panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in one of three different ways:
1, The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a
time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen
in very hot climates).
2, The circ pump stays on continuously, regardless of water temperature.
3, A programmable circ pump will come on when the system is checking temperature (polling), during
filter cycles, during freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be
changed in the field.
Summary of Contents for SAMOA
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 15: ...TROUBLESHOOTING ...
Page 16: ......
Page 31: ...1 Phase Line Connection to 1x16A minimum Advice to SAMOA modell ...
Page 32: ...2 1 Phase Line Connection to 1x25A optimum Advice to SAMOA modell ...