FILTRATION AND OZONE
On non-circ systems, Pump 1 low and the ozone generator (if there is one) will run during filtration. On
circ systems, the ozone will run with the circ pump.
The system is factory-programmed with two filter cycles that will run 10 minutes after power-up. The
filter duration is programmable.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefly to
purge its plumbing to maintain good water quality.
FREEZE PROTECTION
If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and
the blower automatically activate to provide freeze protection. The pump(s) and blower will run either
continuously or periodically depending on conditions.
In colder climates, an optional additional freeze sensor may be added to protect against freeze
conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts
similarly except with the temperature thresholds determined by the switch. See your dealer for details.
CLEAN-UP CYCLE (OPTIONAL)
When a pump or blower (if there is one) is turned on by a button press, a clean-up cycle begins 30
minutes after the pump or blower is turned off or times out. The pump and the ozone generator (if
there is one) will run for 30 minutes or more, depending on the system.
ADJUSTING THE SET TEMPERATURE
When using a panel with Up and Down buttons (Temperature buttons), pressing Up or Down will cause
the temperature to flash. Pressing a temperature button again will adjust the set temperature in the
direction indicated on the button. When the LCD stops flashing, the spa will heat to the new set
temperature when required.
If the panel has a single temperature button, pressing the button will cause the temperature to flash.
Pressing the button again will cause the temperature to change in one direction (e.g. UP). After allowing
the display to stop flashing, pressing the Temperature Button will cause the temperature to flash and
the next press will change the temperature in the opposite direction (e.g. DOWN).
The temperature can be set between 60°F and 104°F.
PRESS-AND-HOLD
If a Temperature button is pressed and held when the temperature is flashing, the temperature will
continue to change until the button is released. If only one temperature button is available and the limit
of the Temperature Range is reached when the button is being held, the progression will reverse
direction.