GENERAL MESSAGES
Priming Mode – M019
Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow
the user to run each pump and manually verify that the pumps are primed (air is purged) and water is
flowing. This typically requires observing the output of each pump separately, and is generally not
possible in normal operation. Priming Mode lasts 4 minutes, but you can exit it earlier by pressing any
Temp button. The heater is not allowed to run during Priming Mode.
NOTE: If your spa has a Circ Pump, it will turn on with Jets 1 in Priming Mode. The Circ Pump will run by
itself when Priming Mode is exited.
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be displayed.
Too Cold – Freeze Protection
A potential freeze condition has been detected, or the Aux Freeze Switch has closed, and all pumps and
blower are activated. All pumps and blower are ON for at least 4 minutes after the potential freeze
condition has ended, or when the aux freeze switch opens.
In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
Water is too Hot (OHS) – M029
One of the water temp sensors has detected spa water temp 110°F (43.3°C) and spa functions are
disabled. System will auto reset when the spa water temp is below 108°F (42.2°C). Check for extended
pump operation or high ambient temp.
Safety Trip - Pump Suction Blockage* – M033
The Safety Trip error message indicates that the vacuum switch has closed. This occurs when there has
been a suction problem or a possible entrapment situation avoided. (Note: not all spas have this
feature.)
* This message can be reset from the topside panel with any button press.