background image

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 
 

 

WARNING: 

RISK OF  INJURY 

 

Installation procedures must 
be performed by a qualified 
technician with full knowledge 
of all applicable electrical and 
plumbing codes.  Failure can 
result in personal injury and 
property damage. 

 

 

CAUTION 

FIRE HAZARD 

 

Avoid storing flammable or 
combustible materials in, on 
or near the appliance. 
 
 

IMPORTANT:  

For warmers 

installed in plastic counter 
tops, the counter material 
must be protected from the 
heat of the warmer in order to 
prevent discoloration and/or 
deterioration.  Wellsloks are 
not suitable for this purpose.  
The installer should contact 
the  manufacturer or distributor 
of the countertop material for 
specific instructions.  

 

 

IMPORTANT

:  Wellslok       

Extension Kits must be used 
ONLY with  UL Listed      
warmers approved  for          
installation in wood counter 
tops. Refer to the 

Installation 

Instructions

 provided with the 

warmer. 

UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 
Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 
Read and understand all labels and diagrams attached to the 
appliance. 

 
Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use.

 

 

INSTALLATION NOTES 

 

     1. 

Installation and start up of built-in warmers MUST be performed 

 

 

by an authorized installation company. 

     2. 

It is the RESPONSIBILITY OF THE INSTALLER to verify that 

 

 

this warmer installation is in  compliance with the specifications 

 

 

listed in this manual and on the specification sheet provided.  

     3. 

It is the RESPONSIBILITY OF THE INSTALLER to check with 

 

 

the AUTHORITY HAVING JURISDICTION, in order  to verify 

 

 

that this warmer installation is in compliance with local code  

   requirements. 
 

4.  Water supply and drain installation must meet all applicable   

 

 

local, state and federal plumbing codes and ordinances. 

 5. 

Refer 

to 

Installation Instructions

 included with the warmer for                

 

 

Underwriters Laboratories conditions of acceptability, electrical          

 

 

requirements and other installation concerns. 

 

BUILT-IN WARMERS

 

 
     1. 

This is a GENERAL GUIDE.  For specific cutout dimensions  

 

 

and other installation details, refer to the 

Installation               

   Instructions

 supplied with the warmer. 

 

 

2.  Cutout dimensions for warmer units and control panels are  

 

 

listed on the 

Installation Instructions 

 provided with the warmer. 

 

 

 

NOTE

:  Cutout dimensions are different for auto-fill and non-auto-fill 

 

control panels, and for wood and metal counters.  Verify the      

 

dimensions are correct for the installation before making the cutout. 

 
      

 

INSTALLATION 

 M
011C.13 

 2M

-308024 

  Owne

rs M

anual for 

Built

-In
 Thre

e-

W
e

ll Au
to-Fill

 M
odular 

 W
a

rmer

Summary of Contents for MOD-300TDMAF

Page 1: ...r TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WE...

Page 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Page 3: ...t performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its...

Page 4: ...indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers may be equipped with WELLSLOKS uniq...

Page 5: ...s must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sch...

Page 6: ...ore starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all a...

Page 7: ...ode E PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installa...

Page 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to preh...

Page 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Page 10: ...spect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fir...

Page 11: ...gher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...n valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto fill unit overflows Water level...

Page 13: ...SEMBLY 503843 208 240V ELEMENT PAN KIT 503842 ELEMENT ONLY 503375 208 240V THERMOBULB ref 55005 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587...

Page 14: ...OBULB ref ELEMENT PAN ASSEMBLY 503701 208 240V sides ends make from 56196 150 roll 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587 50131 61974 O...

Page 15: ...7 503352 503352 ELEMENT PAN KIT 503841 50397 pk 6 500706 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587 50131 61974 OFF 0 L O H I WELLS 2 3 4 5...

Page 16: ...WIRING DIAGRAM 14 M011C 13 2M 308024 Owners Manual for Built In Three Well Auto Fill Modular Warmers...

Page 17: ...NOTES 15 M011C 13 2M 308024 Owners Manual for Built In Three Well Auto Fill Modular Warmers...

Page 18: ...0 warmer to hold one 7qt and one 4 qt 21618 ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets 21623 ADAPTER TOP convert 12 x 27 SMPT 27 to hold three 7 qt insets 21503 2 QT ROUND INSET w lid...

Page 19: ...approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extension...

Page 20: ...STOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA Commercial Food Equipment Service Association WELLS BLOOMF...