background image

OPERATION 

AUTOFILL WARMERS

 

 
 

1.  Autofill warmers sense water level by a sensor placed at the  

 

 

proper level.  For manifolded autofill warmers, the water level 

 

 

sensor / fill tube is in one pan only, normally in the far left pan.   

 

2.  Water fills the pan through an inlet tube.  For manifolded      

 

 

autofill warmers, the fill tube is normally in the far left pan.  All 

 

 

other sections fill at  the same time through the drain manifold. 

 

3.  The autofill function is active only when the thermostat for the 

 

 

pan with the water level sensor is turned 

ON

 .   

 

4.  Make sure the drain valve is fully closed before turning any  

  thermostats 

ON

.   

 

5.  The autofill function is only activated when the far left            

  thermostat 

is 

turned 

ON

.  For manifolded autofill warmers, be 

 

 

sure to turn far left thermostats 

ON

 before turning any other  

  control 

ON

,  to avoid heating a dry pan. 

 

6.  DO NOT use autofill warmers in the dry mode.  This may    

 

 

damage the water level sensor probe.  NEVER turn the         

  thermostat 

ON

 for the pan with the probe and fill tube unless  

 

 

the entire warmer unit is to be used in the wet  mode. 

 

7.  Clean water level sensor daily to maintain water level in   

 

 

warmer. 

 

WARMERS WITH MANIFOLDED DRAIN  

 
 

1.  Manifolded warmers have a single drain valve. 

 

2.  Water poured into any one section will seek the same water  

 

 

level with all sections on the manifold. 

 

3.  Make sure the drain valve is fully closed before filling warmer. 

 

PRE-HEATING THE WARMER 

 

 

1.  Place desired pan(s) or inset(s) with appropriate adapter top on 

   warmer. 
 

 

a.  Insets are available as accessories in 2½ qt., 4qt., 7 qt.,  

 

 

 

and 11 qt. sizes with lids and adapter tops. 

 

 

b.  For dry operation, a 6” deep pan or inset is recommended. 

     2. 

Turn temperature control to HI or highest temperature setting. 

     3. 

Allow warmer to preheat for approximately 30 minutes, then set 

 

 

the control for the desired temperature.  Be sure to keep the  

 

 

warmer covered during preheat and operation. 

 

OPERATION

 

 
     1. 

Always use an inset.

 DO NOT 

place food directly into the  

   warmer. 

 

 

2.  Check water level in wet-operation warmer frequently during  

 

 

use.  Running warmers dry will lower the temperature of the  

 

 

food in the insert pan, and may damage the warmer. 

 

3.  Alternating between wet and dry operation in any individual  

   warmer 

is 

NOT

 recommended. 

 4. 

DO NOT

 use metal tools, steel wool, or caustic or abrasive  

 

 

cleanser to clean warmer pan. 

CAUTION: 

HOT SURFACE 

 

Exposed surfaces can be hot 
to the touch and may cause 
burns. 

 

CAUTION:   

SHOCK HAZARD 

 

DO NOT splash or pour water 
onto control panel or wiring. 
 
Always use an inset.

 

DO NOT 

place food directly 

into the warmer.  

 

Always pour hot water into the 
warmer before it is      
preheated.

   DO NOT 

pour 

water into a dry, heated 
warmer.  This may damage 
the unit.  

 

DO NOT

 put  ice into a 

warmer pan.  This will cause 
condensation on the inside of 
the  warmer.  Damage caused 
by condensation is 

NOT   

covered by warranty. 

 

Stir thick food items frequently 
to keep food heated uniformly. 
Keep insets covered to    
maintain food quality and 
temperature. 
 
DO NOT use autofill      
warmers in the dry mode.  
This may  damage the water 
level sensor. NEVER turn the        
thermostat 

ON

 for the pan 

with the sensor and fill tube 
unless the entire warmer unit 
is to be used in the wet  mode. 

 M
011C.13 

 2M

-308024 

  Owne

rs M

anual for 

Built

-In
 Thre

e-

W
e

ll Au
to-Fill

 M
odular 

 W
a

rmer

Summary of Contents for MOD-300TDMAF

Page 1: ...r TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WE...

Page 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Page 3: ...t performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its...

Page 4: ...indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers may be equipped with WELLSLOKS uniq...

Page 5: ...s must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sch...

Page 6: ...ore starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all a...

Page 7: ...ode E PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installa...

Page 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to preh...

Page 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Page 10: ...spect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fir...

Page 11: ...gher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...n valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto fill unit overflows Water level...

Page 13: ...SEMBLY 503843 208 240V ELEMENT PAN KIT 503842 ELEMENT ONLY 503375 208 240V THERMOBULB ref 55005 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587...

Page 14: ...OBULB ref ELEMENT PAN ASSEMBLY 503701 208 240V sides ends make from 56196 150 roll 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587 50131 61974 O...

Page 15: ...7 503352 503352 ELEMENT PAN KIT 503841 50397 pk 6 500706 67650 503713 67662 68197 68198 66591 65917 51040 503141 60034 50177 50177 54136 54136 66529 66591 66587 50131 61974 OFF 0 L O H I WELLS 2 3 4 5...

Page 16: ...WIRING DIAGRAM 14 M011C 13 2M 308024 Owners Manual for Built In Three Well Auto Fill Modular Warmers...

Page 17: ...NOTES 15 M011C 13 2M 308024 Owners Manual for Built In Three Well Auto Fill Modular Warmers...

Page 18: ...0 warmer to hold one 7qt and one 4 qt 21618 ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets 21623 ADAPTER TOP convert 12 x 27 SMPT 27 to hold three 7 qt insets 21503 2 QT ROUND INSET w lid...

Page 19: ...approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extension...

Page 20: ...STOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA Commercial Food Equipment Service Association WELLS BLOOMF...

Reviews: