background image

Safety instructions and warnings

12/82

1.5

Safety instructions and warnings

1.5.1

Operator's obligations

As the operator you are responsible for providing clear operating, cleaning
and maintenance instructions and ensuring the intended use and the proper
operation of the device by means of training and instruction for the personnel.
Your operating instructions must enable the safe use and safe operation of

the device and take into account the characteristics and expertise of your
company and also the national work safety and environmental protection
regulations (within the European Union, the EU directive 89/391/EEC).
In accordance with Directive 93/42/EEC or 2017/745/EU, accidents or other

incidents involving the dry water massage device must be reported to the
responsible authority – see page 79 .

Commissioning of the device is prohibited in the event of

defective cables,

defective plugs,

defective housing parts,

malfunctions.

1.5.2

Personnel training

The device is only to be used by personnel who are able to accept responsi-
bility for correct operation due to their training, knowledge or practical experi-
ence.
As the operator you are obliged to train your personnel and instruct them in

the established legal and accident prevention regulations. Ensure that your
staff have understood and observe these operation instructions. This applies,
in particular to the

Information in 'Intended use' and 'Foreseeable misuse'

Safety notes in Chapter 1.4 and Chapter 'Operation'

Operating instructions

Cleaning, disinfection and maintenance instructions

Please make the instructions and additional information from the manu-
facturer available to the personnel at their workplace.

Regularly check your personnel's safety consciousness and awareness
of the risks, taking into account your operating instructions.

You must ensure that the cleaning and disinfection intervals are complied
with, in particular cleaning and disinfection after every session.

You must ensure that your staff provide your user/patients with appropri-

ate advice, in particular regarding the types of application, possible risks
and the operation of the device.

Do not allow children to play with the device. Cleaning and user mainte-
nance tasks must not be carried out by children.

1.5.3

Scope of delivery

Information regarding the scope of delivery is contained in the 'Description'
chapter on page 24.

Summary of Contents for MEDWAVE TOUCH

Page 1: ...International GmbH K hlershohner Stra e 60 53578 Windhagen GERMANY Tel 49 0 22 24 818 257 Fax 49 0 22 24 818 254 E Mail contact wellsystem com 1026388 Operating instructions MEDWAVE_TOUCH MEDWAVE_TOU...

Page 2: ......

Page 3: ...1026388 00A en 06 2021 0197 Operating instructions Dry water massage device Date of issue 10 02 2021 Translation of the original operating instructions wellsystem TOUCH MEDWAVE wellsystem...

Page 4: ...com DANGER Failure to observe these instructions can result in serious injury and death can result in damage to the device and the environment Read these instructions carefully before putting this dev...

Page 5: ...bligations 12 1 5 2 Personnel training 12 1 5 3 Scope of delivery 12 1 5 4 Transport assembly and setup 13 1 5 5 Commissioning 16 1 5 6 Operation and maintenance 16 1 5 7 Decommissioning 17 1 5 8 Stor...

Page 6: ...ult massage program 55 3 6 1 Additional massage programmes for massage areas 57 3 6 2 Own programme 57 3 7 Charge credit onto NFC card 59 3 8 LED Light Show 61 4 Cleaning and maintenance 62 4 1 Safety...

Page 7: ...76 7 1 2 Table 202 Guidelines and manufacturer s declaration Electromagnetic interference 77 7 1 3 Table 204 Guidelines and manufacturer s declaration Electromagnetic interference 78 7 1 4 Table 206...

Page 8: ...rvals User Patient Person who uses the dry water massage device at a commercial location Personnel People who are responsible for the operation cleaning and general mainte nance work Electrician A per...

Page 9: ...is safety notice indicates the existence of a direct danger to body and life DANGER Type and source of hazard This safety notice warns of dangers to body and life which are caused by electricity WARNI...

Page 10: ...BF application part Electric unit label do not dispose of via household refuse No continuous operation ESD sensitive components Read the operating instructions Stack a maximum of 2 units Maximum trans...

Page 11: ...ined by your doctor The unit may only be used by people with a heart pacemaker after consulta tion with a doctor 1 2 2 Intended use This device is used to apply a dry water massage to one adult patien...

Page 12: ...UCH must not be carried out Fresh wounds Acute inflammations Infections Suspected phlebitis and thrombosis danger of embolism Severely painful muscle stiffness with additional myogelosis only target e...

Page 13: ...example the following the reference for evi dence that these disease patterns can be treated and alleviated using a mas sage is found in brackets Backache and joint pain belongs to the indication of...

Page 14: ...ning knowledge or practical experi ence As the operator you are obliged to train your personnel and instruct them in the established legal and accident prevention regulations Ensure that your staff ha...

Page 15: ...ce is delivered by a specialist company and assembled and set up by the manufacturer s own service personnel or by an authorized service com pany As the operator you are responsible for abiding by the...

Page 16: ...ect to special preventive measures with regard to the electromagnetic compatibility and must be installed and commissioned according to the EMC instructions obtained from the assembly instructions Ass...

Page 17: ...ately after being set up Wait at least 2 hours before connecting the device to the power supply Environmental conditions Optimum ambient temperature Between 15 C and 32 C Storage and transport tempera...

Page 18: ...ed that must be larger than twice the inner diameter of the supply tube Most effectively the free outlet air bridge prevents the backflow into the public water supply mains High frequency mobile commu...

Page 19: ...table temperature The well pump and hoses must not contain any water Once the unit has cooled off pack it in plastic wrapping to protect it against scratches Storage temperature between 15 C and 60 C...

Page 20: ...EC according to the version valid at the time 1 5 11 Export We emphasize that these devices are only intended for the European market and must not be exported to or operated in other countries e g the...

Page 21: ...hed to the device The signs shown below are examples Ensure that the warning signs are always clearly recognisable and legible Any missing warn ing signs or stickers must be replaced 1a Serial No plat...

Page 22: ...Safety instructions and warnings 20 82 2 ESD sensitive component sticker a and Voltage present warning sticker b 1020257 The sticker is located behind the front panel on the control box...

Page 23: ...Safety instructions and warnings 06 2021 1026388 00A Operating instructions 21 82 3 Warning sticker 1009943 4 Warning sticker type plate pump The sticker is located on the pump...

Page 24: ...and warnings 22 82 5 Note original parts 800702 The sticker is located behind the front panel on the control box 6 No export USA Canada sticker 84829 7 NFC card note sticker 1023746 8 Read instructio...

Page 25: ...Warranty and liability exclusions Warranty and liability claims for personal injury and property damage are excluded if they are the result of one or more of the following causes improper use of the d...

Page 26: ...operating pressure Hose 50909 10 m 1 2 outlet Hand pump for venting 2 1 1 Accessories optional Extension cushion 34528100 NFC card credit programme 2 1 2 Optional Air water cooling wellsystem SPA COM...

Page 27: ...Description 06 2021 1026388 00A Operating instructions 25 82 2 2 Device description 1 Operating unit with touch function 2 Neck support 3 Tank 4 Bed surface rubber blanket 5 LED Light Show 6 NFC point...

Page 28: ...is completely avoided with this device The person does not make bodily contact with the water jets The risk of a water borne infection is therefore also eliminated Mechanical massage using this devic...

Page 29: ...operation without an NFC card if the appropriate icon is pressed Button Function Button Function Full body massage Back massage For the full body mas sage the massage noz zles move along the entire b...

Page 30: ...sage the massage nozzles move in a circle on the bed in the massage area defined in the pre selection 2 4 3 Control panel key lock The control panel is fitted with a key lock to prevent the user patie...

Page 31: ...Operating instructions 29 82 Enter the PIN code by tapping the numbers Confirm with The screen can be locked for the patient by activating the key lock mode switch NOTE The maximum intensity and the i...

Page 32: ...uld therefore be removed beforehand Light weight and strong clothing should always be worn during use Lie down with your back on the device People with disorders and injuries that are listed on page10...

Page 33: ...2 Language 3 Instructions on the current Menu selection 4 User specific settings body size shoulder width 5 Type of massage quick start button 6 Unit settings menu Setup Manager 7 Home Setup Manager...

Page 34: ...time until the massage screen is automatically exited can be changed in the Setup Manager NOTE Where video option is activated To interrupt or end the video briefly tap on the screen sur face of the o...

Page 35: ...g body size by tapping the numbers Switch on and off by tapping Select the desired function by tapping Setting the menu language The language can be changed by tapping the flag icon The selection is m...

Page 36: ...al window opens up when the operating unit is tapped Changing body size An additional window opens up when the Body size icon is tapped NOTE Only those languages are displayed which have been se lecte...

Page 37: ...up function and Memory function on NFC card are activated in the Setup Manager The current Memory func tion on NFC card status can be viewed and changed in the Setup Manager see chapter System settin...

Page 38: ...Operation 36 82 Enter the PIN code Confirm with NOTE The factory set PIN code is 0000 Lie down on the unit In doing so lay your head in the neck support Begin massage with...

Page 39: ...the pre settings or on the activation of the key lock see Setup Manager page 73 Massage time NOTE The massaging pressure can be decreased or increased at any time while the unit is working The type of...

Page 40: ...ped NOTE Only those languages are displayed which have been se lected in the Setup Manager The entered body size can be changed by tapping the numbers A body size between 130 cm and 220 cm can be sele...

Page 41: ...rt button NOTE The programme Own programme is available if NFC card top up function and Memory function on NFC card are activated in the Setup Manager The current Memory func tion on NFC card status c...

Page 42: ...Operation 40 82 Lie down on the unit In doing so lay your head in the neck support Begin massage with...

Page 43: ...Setup Manager page 73 Massage time Changing body size An additional window opens up when the Body size icon is tapped NOTE Only those languages are displayed which have been se lected in the Setup Ma...

Page 44: ...ailable as a quick start button NOTE The programme Own programme is available if NFC card top up function and Memory function on NFC card are activated in the Setup Manager The current Memory func tio...

Page 45: ...dow opens up when the operating unit is tapped Changing body size An additional window opens up when the Body size icon is tapped NOTE Only those languages are displayed which have been se lected in t...

Page 46: ...e programme Own programme is available if NFC card top up function and Memory function on NFC card are activated in the Setup Manager You can call up and change the current Memory function on NFC stat...

Page 47: ...on and off automatically whilst the device is being used Lie down on the unit In doing so lay your head in the neck support Begin massage with 3 3 4 Settings during the massage The following settings...

Page 48: ...hs point massage Programme 6 Full body lymphatic massage Programme 7 Legs lymphatic massage Programme 8 Thighs lymphatic massage Programme 9 Legs massage programme Programme 10 Back massage programme...

Page 49: ...con Confirm selection with After choosing the Individual massage type In the Massage menu Select body area Select massage technique Change intensity Change speed Tap on the appropriate icons to make t...

Page 50: ...Stay in position A massage is aborted by tapping To confirm the selection tap Change Massage technique Tap on one of the icons to change the massage technique Confirm selection with The Pulsating func...

Page 51: ...Operation 06 2021 1026388 00A Operating instructions 49 82 Setting Intensity Tap on or to change the values Setting Speed Tap on or to change the values...

Page 52: ...int on the screen or using the arrow keys The parameter intensity and massage duration in seconds can be defined and stored with Tap to open Reporting of reference run and then an additional window NO...

Page 53: ...reduced Do not get off the massage unit until the nozzle carriage has reached one of the end positions Confirm with NOTE The NFC save prompt appears only if the save function is enabled in the Setup...

Page 54: ...ly transferred from the data carrier The middle of the NFC point is blue Settings have been successfully transferred to the data carrier The middle of the NFC point is orange a Transmission error Hold...

Page 55: ...00A Operating instructions 53 82 NOTE Whether the pause function can be used depends on the pre settings see Setup Manager page 73 Massage time 3 4 2 Terminating the massage before the time has expire...

Page 56: ...ce card The NFC service card 1023744 is used to call up infor mation via the unit and to modify certain pre set values e g the water temperature see page 73 NOTE The NFC service card 1023744 can only...

Page 57: ...1026388 00A Operating instructions 55 82 3 6 Default massage program There are 9 therapeutic massage programmes saved on the unit The following summary shows which muscle groups are affected by the sp...

Page 58: ...L3 M iliocostalis lumborum 4 Ileo sacral area 5 Buttocks M piriformis gluteal muscles 6 Thigh dorsal area M biceps femoris M rectus femoris 7 Calf muscles M gastrocnemius M soleus Dwell time in the i...

Page 59: ...NFC service card after the end of the session NOTE An Own programme can be created In this the unit stores all changes desired by the therapist during the massage The massage can be stored via NFC on...

Page 60: ...programme Place the NFC card with a previously stored massage pro gramme onto the NFC point Select Own programme Configure possible individual settings Set intensity Tap on or to change the values Con...

Page 61: ...ed up as much as you wish for further massages see Pre settings Setup Manager Top up credit Topped up NFC cards briefly display the number of massages remaining after they have been placed on the NFC...

Page 62: ...Operation 60 82 Confirm with Place NFC card on the NFC point until the LED lights up green The credit has been successfully written onto the NFC card Credit minutes are displayed...

Page 63: ...tapping the numbers note min and max Confirm with Place NFC card on the NFC point until the LED lights up green The credit has been successfully written onto the NFC card 3 8 LED Light Show The LED li...

Page 64: ...must be switched off Switching off the device alone is insufficient as certain points may remain energized Therefore switch off fuses before performing any work and if possible remove them Accidental...

Page 65: ...ror code is dis played again after pressing the START STOP button or switching the device back on see page 2 More detailed information regarding the error description and solutions can be found in Err...

Page 66: ...ikrozid sensitive wipes refill pack 200 wipes Order no 1010286 INSTRUCTIONS To ensure thorough disinfection always adhere to the contact time specified for the disinfectant Follow the manufacturer s i...

Page 67: ...ids containing alcohol must never be used for cleaning Remove fingerprints cleaning residues and other soil ing carefully Plastic surfaces For cleaning the painted and unpainted plastic surfaces it is...

Page 68: ...th checklist 1016789 by a JK Factory Certified Technician at the manufacturer or by personnel who have been authorized trained and qualified by the manufacturer The correctly carried out maintenance w...

Page 69: ...n if there are leaks or if it is damaged Inform our customer service department see page 2 4 5 2 Venting The tank must be vented 3 days after commissioning or after it has been initially filled After...

Page 70: ...ve the hose and shut off valve Place a collection container underneath the shut off valve Remove the shut off valve seal Connect the shut off valve of the hose system to the hand pump NOTE Observe the...

Page 71: ...uctions 69 82 Close the shut off valve Remove the hand pump Reconnect the shut off valve of the hose system to the hand pump NOTE Observe the direction of flow Open the shut off valve Pump until water...

Page 72: ...st electric shock Protection class I Type BF application part rubber blanket CSM natural rubber Protection class I Protection type IP20 Empty weight unfilled approx 168 kg Weight approx 472 kg Non con...

Page 73: ...without additives The water can be drained off into the public sewage system after it has been used Water and cooling conditions Permissible water pressure water inlet 0 8 MPa 8 bar Maximum coolant t...

Page 74: ...00 mm A3 310 mm A4 220 mm A5 90 mm A6 90 mm A7 150 mm A8 250 mm A9 90 mm A10 150 mm A11 440 mm BK 2450 mm TK 1900 mm L 2291 mm H 585 mm H1 2350 mm T 1050 mm T1 1260 mm B 1050 mm L 2291 mm 5 4 Spare pa...

Page 75: ...nfiguring the settings 6 1 Unit settings Setup Manager NOTE The Setup Manager can only be called up outside a mas sage By tapping on the unit automatically switches into standby mode and the currently...

Page 76: ...saved NOTE The master code allows you to access all of the default set tings If you know the current master code you can specify a new code at any time If you have forgotten the code you can reset th...

Page 77: ...ss on Permissions during use Change by tapping Setup code Enter the PIN code by tapping the numbers Confirm with 6 1 2 Operation of the Setup Manager The description of the function is displayed by ta...

Page 78: ...r solely for internal functions Therefore the HF emissions are very low and it is highly unlikely that it will cause any interference to adjacent electronic equipment HF emissions as per CISPR 11 Clas...

Page 79: ...t discharge 2 kV air discharge 4 kV air discharge 8 kV air discharge 15 kV air discharge Fast transient electrical noise bursts IEC 61000 4 4 2 kV for mains supplies 2 kV for mains supplies Surges 610...

Page 80: ...V m 710 745 780 MHz Modulation Pulse Modulation 217 Hz 28 V m 810 870 930 MHz Modulation Pulse Modulation 18 Hz 28 V m 1720 1845 MHz Modulation Pulse Modulation 217 Hz 28 V m 1970 2450 MHz Modulation...

Page 81: ...Hz 800 MHz to 2 7 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 The recommended safe distance d in metres m can be determined by using the equation that applies...

Page 82: ...indications 10 Cooling conditions 72 Customer service 2 D Decommissioning 17 Default massage program 55 Definitions 6 Description 25 Device description 25 Device operating time 16 Dimensions 73 Direct...

Page 83: ...ge 45 Massage start 34 Massage technique 28 Massage types 27 Master code 75 N NFC chip card Charging credit 59 NFC service card 54 O Operating altitude 15 Operating overview 31 Operating water Disposa...

Page 84: ...ns 12 Scope of delivery 12 24 Setup 13 Setup location 15 Size 73 Spare parts Order numbers 73 Start 34 Coin unit 40 NFC chip card 37 without payment NFC card or PIN code 43 Storage 17 Symbols 7 T Tech...

Page 85: ......

Page 86: ...International GmbH K hlershohner Stra e 60 53578 Windhagen GERMANY Tel 49 0 22 24 818 257 Fax 49 0 22 24 818 254 E Mail contact wellsystem com 1026388 Operating instructions MEDWAVE_TOUCH MEDWAVE_TOU...