3.2 Line
The Line configuration will show the status of the registrations and the ports. It
includes the hunt group, hotline, and no answer forward configuration. Press
the Line configuration button to enter configuration table (see figure 3.14)
Figure 3.4: Line Configuration
Type – Show the type of this port. There are only two types of this gateway.
One is FXS type another is FXO type. It couldn’t be changed.
Hunting Group – Define the group number of this port. When the port is
busy, the call could be transferred to another port in the same group.
Hotline – Enable or Disable the hotline mode. The hotline mode will be
enabled if you enter the hotline number. The default setting is disabled.
No Answer Forward – When the port didn’t answer the call, this call will be
forwarded to the number you configured. This is only for the E164 number
or the phone number you want to transfer.
This function should be used with the forwardtime command (in the System
configuration table). The range of the forward time is 5 to 65535. If the
function is enable, the No Answer forward number is 123, and the forward
time is 5 seconds. The call will be forwarded to the destination with 123