background image

WEMPE ENI 

secondary clocks interface

2  Operating controls 

During  normal  clock  operation,  there  is  no  need  to  access  to  the  operating  controls.  In  case  of 
troubleshooting the controls can be accessed after opening the ENI's housing. 

2.1  Switches 

Lights 

During normal clock operation, there is no need to let the LEDs (see next chapter) flicker all the time. 
For installation and maintenance the LEDs can be activated by setting the "Lights" switch to "ON". 

Power up (Start options) 
Set_SEC 

Force  the  network  initialization  to  use  the  DHCP  client.  This  is  an  emergency  option  to 
set a usable IP address even if the ENI is configured to use a static address that can not 
be reached in its subnet. 

This  option  requires  a  working  DHCP  server  on  the  same  subnet  that  the  ENI  is 
connected to. 

Set_MIN 

Force  the  network  initialization  to  use  the  static  IP  address  172.16.0.100,  which  is  the 
factory  setting.  This  is  an  emergency  option  to  set  an  IP  address  even  if  the  ENI  is 
configured to use a DHCP server that can not be reached in its subnet. 

This option may require reconfiguring the maintenance PC to use the same subnet. 

12h 

Start the bootloader even if a working firmware is present. This is an emergency option 
for firmware updates while all other access methods fail. 

 
Set_MIN 
10 sec. 

Restore the ENI's factory settings. During the 10 seconds the State- and the Error LED 
flash alternating. When finished the LEDs stay off until the buttons are released and the 
ENI restarts. 

For more functions refer to the ENI user manual. 

Lights 

Service 

Set_SEC 

Set_MIN 

12h 

Summary of Contents for 20804/IP

Page 1: ...d and glass frame Geh use Housing Messing hochglanz verchromt brass high gloss chrome plated Abmessungen mm Dimension mm 232 H he 65 232 height 65 Zifferblatt mm Dial mm Aluminium wei 230 aluminium wh...

Page 2: ...mmleiste Terminal block Ersatzteile spare parts TypE T Type IP Art No Beschreibung description ENI v3 WEMPE Ethernet Secondary clock interface Connector RJ45 Ethernet 10Base T IPv4 network cable twist...

Page 3: ...die Buchse am Zeiger etwas zusammengedr ckt werden Setzen Sie danach den Minutenzeiger auf die Minutenachse und ziehen Sie die Stiftschraube M2 der Buchse fest an Es ist darauf zu achten dass zwische...

Page 4: ...ghtly squeezed Then place the minute hand on the minute arbour and tighten the pin screw M2 of the liner Please pay attention that there is enough space between the hands To check this turn the minute...

Page 5: ...ce ENI Ethernet Secondary Clocks Interface Quick Start Guide valid for Hardware Rev 3 0 03 10 2016 Firmware V3 05 05 12 2016 V3 06 22 12 2016 Secondary Clock Ethernet Interface Compatible with Wempe M...

Page 6: ...tatic by default This can be changed to obtain addresses from a DHCP server The DHCP query asks for addresses of NTP servers too If the DHCP server provides them up to two addresses will be mentioned...

Page 7: ...to reconnect the web browser after a few seconds Further ENI configuration can be done on the Master Clock s web interface see it s manual Master Clock Rev Master Clock Software Version1 Select ENI V...

Page 8: ...subnet This option requires a working DHCP server on the same subnet that the ENI is connected to Set_MIN Force the network initialization to use the static IP address 172 16 0 100 which is the facto...

Page 9: ...ng off INIT Can t finish initialization most likely the device is damaged MAC No physical network connection LINK Network up but doesn t respond to IP requests CONN Network up but no IP address possib...

Page 10: ...one user name and one password There is no way to add or delete account names There is no limit in the count of failed logins due to wrong passwords To protect the web interface access against brute...

Page 11: ...s from PC to ENI and back The ping tool on the Tools page of the web interface see ENI user manual can assist Check any blocking features firewall etc at every routing device between ENI and PC Try us...

Page 12: ...2 to set the correct protocol version Check the IP addresses of ENI and masterclock are in the same IP subnet or VLAN The ping tool on the Tools page of the web interface see ENI user manual can assis...

Reviews: