21
Spindle speed readout
does not display proper
speeds or any readout.
1. Spacing between the
sensor ad the timing gear is
incorrect.
1. Adjust spacing between sensor and timing gear.
2. Sensor has gone bad or
has poor/damaged wiring.
2. Inspect sensor and associated wiring or call cus-
tomer service
(1-800-232-1195)
for assistance.
Digital depth readout
does not display proper
measurement or does
not turn on.
1. Initial measurement is
incorrect.
1. Zero/Reset the depth readout at the zero point.
2. Sensor battery needs
replacement.
2. Replace sensor battery.
3. Sensor has gone bad or
has poor/damaged wiring.
3. Inspect sensor and associated wiring or call cus-
tomer service
(1-800-232-1195)
for assistance.
TROUBLESHOOTING GUIDE
WARNING!
Stop using the generator immediately if any of the following problems occur or risk serious
personal injury. If you have any questions, please contact customer service at
1-800-232-1195
(M-F 8-5 CST),
or email
techsupport@wenproducts.com
.