20
MAINTENANCE & CARE
STORAGE & TRANSPORT PROCEDURES
DRAINING THE FUEL TANK
Clean fuel tank each year or before storing the generator for extended periods of time. To drain the fuel tank and
carburetor:
1. Remove the fuel cap; carefully turn the generator over to pour the gasoline in the fuel tank to appropriate con-
tainer.
2. Start generator without any device connected to it until it stops. This burns out the fuel in the carburetor and
fuel line.
3. Store the emptied gasoline in a suitable place.
CAUTION:
Do not store fuel for more than 3 months.
CAUTION:
Never place any type of storage cover on the generator while it is still hot.
If the generator is being stored for short periods of time (30 to 60 days), add stabilized fuel to the fuel tank until
full. NOTE: Filling the tank reduces the amount of air in the tank and helps reduce deterioration of fuel. Run
the engine for 2 – 3 minutes allowing stabilized fuel mixture to circulate through the carburetor.
When storing the generator for extended periods of time:
•
Drain the fuel tank (see “Draining the Fuel Tank” in the “Maintenance” section).
•
Change oil.
•
Do not obstruct any ventilation openings.
•
Keep the generator in a cool dry area.
When transporting generator:
•
Keep the generator upright. Never place the generator side down. Doing so will make it difficult to start.
Summary of Contents for 56310i
Page 38: ......
Page 40: ...Thanks for remembering...