13
ASSEMBLY & ADJUSTMENTS
Fig. 3
Fig. 4
Fig. 5
INSTALLING THE CHUTE (FIG. 3)
1. Place the chute assembly (A) onto the rotator ring (B)
on the impellar housing.
2. Use the three positioning plates (C), six M6x12 bolts
(D), and six M6 locking nuts (E) to secure the chute as-
sembly to the rotator ring (B).
NOTE:
Do not over-tighten the lock nuts, or the chute
will not be able to rotate. Rotate the chute assembly
by hand; if you find that the chute is difficult to ro-
tate, slightly loosen the lock nuts. Make adjustments
as necessary until the chute rotates freely, but does
not wobble, on the housing. It should be securely
mounted.
NOTE:
Ensure that the spiral vanes on the chute ro-
tator handle assembly rest in the notches on the side
of the chute base.
NOTE:
Adjust the nut on the eye bolt, if necessary, to
make it easier to assemble.
INSTALLING THE CHUTE ROTATOR HANDLE
ASSEMBLY (FIG. 4 & FIG. 5)
1. Assemble the front end of the chute rotator as shown
in
Fig. 4
, using the 10mm washers (A/B) and cotter pin
(C). Bend back the ends of the cotter pin to secure it.
2. Assemble the rear end of the chute rotator (F) as
shown in
Fig. 5
, using the bolt (A), knob (B), bent
washers (C), eye bolt (D), and nut (E).
3. Check that rotating the chute rotator handle causes
the chute to rotate. Adjust mounting nuts if necessary,
see "INSTALLING THE CHUTE (Fig. 3)" on page 13.