6. Functions
6.1 Default Settings
Device
Function
Default Setting
Receiver
Safety mode
Active (in the case of appropriate wiring)
Start-up and
restart inhibit
Inactive, is activated automatically by means of appropriate wiring
Contactor
monitoring
Inactive, is activated automatically by means of appropriate wiring
Emitter
Test function
Inactive, is activated when triggered during operation
Range
High range (in the case of appropriate wiring)
6.2 Function definition
Safety Mode (automatic operation)
[
abc
]
• In this operating mode, the switching outputs are disabled when the safety field is interrupted.
The switching outputs are automatically enabled after interrupted of the safety field is ended.
NOTE!
• Determine whether or not safety mode operation is permissible for the respective application.