Testing the effectiveness of the ESPE:
• Testing may only be conducted when hazardous motion has been switched off.
• Testing must be conducted with a test rod, and not by reaching in with the hand.
• Test rod diameter: in accordance with ESPE resolution
Testing the “automatic start-up function” (safety mode):
• The OSSD ON display must light up before testing is started.
• Pass the test rod through the entire safety field as shown in the figure.
• The OSSD OFF display must be lit up as long as the test rod is in the safety field.
Testing the “restart inhibit” function:
• The RES display must blink before testing is started.
• Pass the test rod through the safety field as shown in the figure.
• The OSSD OFF display must remain lit up as long as the test rod is in the safety field.
• The RES display may not light up as long as the test rod is in the safety field.
Receiver
Emitter
NOTE!
• Work at the machine must be immediately stopped if any impairment of the safety function
is detected.
• Do not clean with solvents or cleansers which could damage the device.
• Attach the included sticker, “Important Instructions for Daily Inspection”, in direct proximity
to the associated Safety Light Curtain