5 Incorporation into the Machine
Have both OSSDs been incorporated into the downstream machine controls?
Yes
No
Have they been connected in accordance with the wiring diagrams?
Yes
No
Are the switching elements which are controlled by the ESPE (e.g. contactors, valves)
monitored by EDM?
Yes
No
Have required protective measures against electric shock been effectively implemented?
Yes
No
6 Functionality
Is the ESPE effective during the entire duration of the machine’s hazardous motion?.
Yes
No
Is hazardous motion stopped when the ESPE is disconnected from supply power, and
does the acknowledgment key have to be activated in order to reset the machine after
supply power has been restored?
Yes
No
If a hazardous state has been initialized, is it stopped when the ESPE is switched off, if the
operating mode or any of the function types are changed, or if switching to another safety
device occurs?
Yes
No
Are the specified safety functions effective in all of the machine’s operating modes?
Yes
No
Has the safety function been tested in accordance with the inspection instructions in the
operating instructions?
Yes
No
Have the instructions for daily Inspection of the ESPE been attached such that they are
plainly visible and legible for operating personnel.
Yes
No