The MV_Aptr_CB-36_V1.0 measuring amplifier
ATTENTION!
The measuring amplifier may only be plugged in when it is disconnected from the power supply!
Non-compliance can lead to the destruction of the measurement converter or the I/O board!
7.4
External functions
7.4.1
Input External OFF – release contact
The external OFF input is used for the controlled deactivation of the POOLKLAR Touch Basic via the swimming pool filter system’s
central control. As long as the contact is open, there is no dosing, no heating of the pool water, no alarm message given.
7.4.2
Temperature control
The device is equipped with a temperature control. This temperature control can be used to regulate the pool water temperature.
If the pool is heated by means of a flow-through heat exchanger, it must be ensured that the associated heating circuit pump may
only be activated when the filter system is in operation!
Please remember that the regulation of the pool temperature can only be guaranteed if the filter operation times are set to an
appropriate duration.
In order to achieve a precise measuring result, the sensor must be installed by means of an immersion sleeve in the swimming
pool’s piping.
ATTENTION!
Immersion sleeves must be corrosion-proof!
ATTENTION!
Please pay attention to the safety notices regarding the topic of temperature control in the menu!