nspection:

Official periodic inspection must be performed at least annually. 

The inspection must be performed by a competent or qualified person other than 

the intended user. If severe weather or conditions exist then inspections must be 

carried out more frequently. All inspection results must be logged in the space 

provided above.

 

1. Ensure all labeling is affixed to the unit.

 

2. Inspect anchoring system for signs of damage or wear.

 

3. Record inspection results in the space provided above.

*If inspection reveals any damage that could affect the strength or operation of 

the device, inadequate maintenance, or an unsafe condition, proper disposal 

is required. The anchorage connector must be rendered unusable and then 

properly discarded.

 

 

 

Part Number

Comments

Inspector Name

INSPECTION AND MAINTENANCE LOG

Date

MODEL NUMBER:

DATE OF MANUFACTURE:

MAINTENANCE, CLEANING AND STORAGE

Cleaning periodically will prolong the life and proper functioning of the product. The frequency 

of cleaning should be determined by inspection and by severity of the environment. Clean with 

compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use 

any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth 

and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, 

clean environment, out of direct sunlight and free of corrosive or other degrading elements.

Summary of Contents for A114002

Page 1: ...DERSTAND ALL INSTRUCTIONS FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL USERS OF THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MAKE ONLY COMPATIBLE CONNECTIONS ...

Page 2: ...chorage connector has been tested in compliance with the requirements of ANSI ASSE Z359 7 Compliance testing covers only the hardware and does not extend to the anchorage and substrate to which the anchorage connector is attached The anchorage connector must not be used outside its limitations or for any purpose other than that for which it is intended If this anchorage connector is used different...

Page 3: ...h MBS 5000 lbf 22kN DIMENSIONS Length 2 feet 3 feet or 6 feet REGULATORY COMPLIANCE ANSI Z359 18 Type A ANSI Z359 7 19 OSHA 29 CFR 1926 502 OSHA 29 CFR 1910 140 COMPONENT MATERIALS Aircraft Cable Polyurethane Zinc Plated Steel Zinc Plated Copper 1 inch Ø 25 inch Ø Spherical Spacer Wheel 1 85 inches Ø Wheel 30 inch Ø Ball Bearing ...

Page 4: ... or small diameter structural members that could lessen structural integrity of the anchorage connector Only make compatible connections Due to the risk of improper loading roller sling terminations must not be connected to each other by a single snaphook Only OSHA compatible connections such as a Y lanyard or Werner A100303 are permitted ...

Page 5: ...OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT DECK FLOOR GROUND LEVEL All products subjected to fall arresting forces should be removed from service immediately WORK SURFACE WORK SURFACE MINIMUM CLEARANCE 2 feet 6m ...

Page 6: ...WARNING LABEL LOCATION DO NOT REMOVE WARNING LABEL ...

Page 7: ...ition proper disposal is required The anchorage connector must be rendered unusable and then properly discarded Part Number Comments Inspector Name INSPECTION AND MAINTENANCE LOG Date MODEL NUMBER DATE OF MANUFACTURE MAINTENANCE CLEANING AND STORAGE Cleaning periodically will prolong the life and proper functioning of the product The frequency of cleaning should be determined by inspection and by ...

Page 8: ...Werner Co 93 Werner Road Greenville PA 16125 1 888 523 3371 www wernerco com P N 124587 01 REV B 4 21 ...

Reviews: