I
nspection:
Official periodic inspection must be performed at least annually.
The inspection must be performed by a competent or qualified person other than
the intended user. If severe weather or conditions exist then inspections must be
carried out more frequently. All inspection results must be logged in the space
provided above.
1. Ensure all labeling is affixed to the unit.
2. Inspect anchoring system for signs of damage or wear.
3. Record inspection results in the space provided above.
*If inspection reveals any damage that could affect the strength or operation of
the device, inadequate maintenance, or an unsafe condition, proper disposal
is required. The anchorage connector must be rendered unusable and then
properly discarded.
Part Number
Comments
Inspector Name
INSPECTION AND MAINTENANCE LOG
Date
MODEL NUMBER:
DATE OF MANUFACTURE:
MAINTENANCE, CLEANING AND STORAGE
Cleaning periodically will prolong the life and proper functioning of the product. The frequency
of cleaning should be determined by inspection and by severity of the environment. Clean with
compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use
any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth
and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry,
clean environment, out of direct sunlight and free of corrosive or other degrading elements.