8.2 USING A BALANCED WHEEL
Mount on the machine an already balanced wheel (with steel rim), input the wheel data and
apply on the external side of the wheel a 80 gr. Counterweight.
Close the wheel cover and press
START
to proceed to the calibration spin,
When the calibration cycle will end the display will show values 0 and 80 (79 is also accepted)and it
means that the calibration of the machine was well done.
Press
START
again to exit from the CALIBRATION page and enter in a normal balancing mode.
ATTENTION:
If the wheel used for calibration is not balanced, the machine will not
calibrate correctly. Even though it may seem that the cycle has successfully
completed, following measurements will be afflicted by errors resulting from the
incorrectly executed calibration.
8.3 BALANCING A WHEEL BEFORE USING FOR CALIBRATION
To balance a wheel before using it for calibration go to the balancing program, set the threshold to
"0"and start a measurement. If there is no unbalance and two zeroes appear, the wheel is
balanced and may be used to calibrate the machine. Otherwise it should be balanced until a
control measurement shows zero in both sides of the wheel. Only then calibration can be
performed as described in chapter 8.2.