3.
Front panel
1 Input –Determines the level of the input signal entering the compressor, as well as the
threshold. Higher settings will increase amounts of compression or limiting.
2 Output – Determines the level of the output signal leaving the compressor. It is used to recover
compression lost signal.
3 Attack – It sets the Attack time from 20 microseconds to 800 microseconds. The attack time is
fastest when the Attack knob is in fully clockwise position, and it’s slowest when it’s in its fully
counterclockwise position
4 Release – It sets the Release time from 50 millisecond to 1100 milliseconds. The release time is
fastest when Release knob is in its fully clockwise position, and is slowest when it is in its fully
counterclockwise position.